4.2 Article

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

Journal

EARTHQUAKES AND STRUCTURES
Volume 23, Issue 6, Pages 517-526

Publisher

TECHNO-PRESS
DOI: 10.12989/eas.2022.23.6.517

Keywords

base isolation; centrifuge shaking table test; earthquake; pile-soil interaction; pile foundation structure

Funding

  1. National Natural Science Foundation of China
  2. [52178295]

Ask authors/readers for more resources

In this study, the seismic response of a friction pendulum bearing isolated structure with a pile foundation under earthquakes was simulated using a centrifuge shaking table. The study found that soil structure interaction has a significant influence on the seismic performance of the structure, and the rotation of the soil is a key factor.
Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available