4.3 Article

Simulation of the transient flow in a natural gas compression system using a high-order upwind scheme considering the real-gas behaviors

Journal

JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING
Volume 28, Issue -, Pages 479-490

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.jngse.2015.12.012

Keywords

Centrifugal compressor; Emergency shutdown; Recycle valve; Surge avoidance; Finite volume method

Funding

  1. National Natural Science Foundation of China [51306209]
  2. Science Foundation of China University of Petroleum, Beijing [YJRC-2013-43]

Ask authors/readers for more resources

The transient flow in a pipe flow network was numerically simulated to study the performance of the surge avoidance system in a natural gas compression station. The simulation was performed based on a combined approach that the flow in the pipe was simulated using a finite volume method with a high order upwind scheme considering the real-gas behaviors and the behaviors of elements (e.g., compressor and valve) were evaluated using quasi-steady models. In the pipe flow simulation, characteristic boundary conditions were used to couple with the quasi-steady modeling of elements. The numerical scheme for the pipe flow simulation was first used to predict the rapid transients in a single pipe after the sudden closure of a downstream valve. The predicted distributions of the flow properties indicated that the present numerical scheme was capable of simulating the pipe flow under extreme flow conditions with high order of accuracy. The present approach was further used to simulate the transient flow during the emergency shutdown of compressor in an experimental piping network. Simulation results, including traces of operating points and histories of pressures at both sides of the compressor, were compared to the corresponding experimental data, and an agreement with a maximum deviation less than 10% was obtained in the primary control stage. The agreement proved the accuracy of the present approach for the simulation of the transient flow in a piping network and its validity in evaluating the performance of the surge avoidance system in a natural gas compressor station. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available