4.5 Article

Experimental investigation of GFRP-reinforced concrete columns made with waste aggregates under concentric and eccentric loads

Journal

STRUCTURAL CONCRETE
Volume 24, Issue 1, Pages 1670-1688

Publisher

ERNST & SOHN
DOI: 10.1002/suco.202200624

Keywords

ductility; eccentric loading; GFRP-reinforced columns; RC column; recycled coarse aggregates

Ask authors/readers for more resources

This study aims to investigate the influence of recycled coarse aggregates (RCA) on the structural performance of GFRP-reinforced concrete columns. The results showed that incorporating RCA can improve the axial resistance of the columns, especially when the stirrup spacing is smaller.
Nowadays, reducing the waste and recycled material resources in nature and environmental protection, as well as reducing the use of natural resources, has gained the attention of engineers and researchers. One of the ways to reach this goal is to use waste and recycled materials in new concrete members' construction. Additionally, using glass fiber-reinforced polymer (GFRP) rebars has gained high consideration owing to their advantages such as high tensile strength and corrosion resistance. Therefore, this study aims to measure the influence of recycled coarse aggregates (RCA) on the structural performance of reinforced concrete (RC) columns reinforced by GFRP rebars under concentric and eccentric loading conditions. A total of 24 RC columns were cast and subjected to concentric and eccentric loads with different eccentricity ratios (e/h):0 (no eccentricity), 0.25 (moderate eccentricity), and e/h = 0.5 (high eccentricity). A total of 18 columns were strengthened with longitudinal GFRP rebars, and six specimens were considered control samples reinforced by steel rebars. RCA was used at two contents of 0% and 100% in terms of weight as a substitute for natural coarse aggregates (NCA). In addition, to measure the influence of transverse reinforcement, three different spacings were considered: 60, 120, and 180 mm. Evaluation of axial behavior, the strain of rebars and concrete, and the ductility were the main aims of this study. Moreover, a comparison between the experimental results and existing standards was carried out. Findings revealed the adequate axial resistance of specimens when RCA was used. Therefore, RCA incorporation improved the axial resistance of GFRP-RC columns by about 25% and 35% when the stirrup spacing declined by 60 and 120 mm, respectively in comparison with the same specimens made with NCA. However, the influence of RCA on the RC columns' axial behavior was declined by raising the eccentricity distance.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available