4.7 Article

MR-self Noise2Noise: self-supervised deep learning-based image quality improvement of submillimeter resolution 3D MR images

Journal

EUROPEAN RADIOLOGY
Volume 33, Issue 4, Pages 2686-2698

Publisher

SPRINGER
DOI: 10.1007/s00330-022-09243-y

Keywords

Magnetic resonance imaging; Quality improvement; High-resolution; Deep learning

Ask authors/readers for more resources

This study developed a deep neural network (DNN)-based method for noise reduction and image quality improvement in 3D high-resolution MRI using only routine clinical scans. The DNN model outperformed conventional methods in terms of image quality and quantitative evaluation, and also showed promising results in vessel wall imaging.
Objectives The study aimed to develop a deep neural network (DNN)-based noise reduction and image quality improvement by only using routine clinical scans and evaluate its performance in 3D high-resolution MRI. Methods This retrospective study included T1-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) images from 185 clinical scans: 135 for DNN training, 11 for DNN validation, 20 for qualitative evaluation, and 19 for quantitative evaluation. Additionally, 18 vessel wall imaging (VWI) data were included to evaluate generalization. In each scan of the DNN training set, two noise-independent images were generated from the k-space data, resulting in an input-label pair. 2.5D U-net architecture was utilized for the DNN model. Qualitative evaluation between conventional MP-RAGE and DNN-based MP-RAGE was performed by two radiologists in image quality, fine structure delineation, and lesion conspicuity. Quantitative evaluation was performed with full sampled data as a reference by measuring quantitative error metrics and volumetry at 7 different simulated noise levels. DNN application on VWI was evaluated by two radiologists in image quality. Results Our DNN-based MP-RAGE outperformed conventional MP-RAGE in all image quality parameters (average scores = 3.7 vs. 4.9, p < 0.001). In the quantitative evaluation, DNN showed better error metrics (p < 0.001) and comparable (p > 0.09) or better (p < 0.02) volumetry results than conventional MP-RAGE. DNN application to VWI also revealed improved image quality (3.5 vs. 4.6, p < 0.001). Conclusion The proposed DNN model successfully denoises 3D MR image and improves its image quality by using routine clinical scans only.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available