4.7 Article

Fully Implantable Neurostimulation System for Long-Term Behavioral Animal Study

Related references

Note: Only part of the references are listed.
Review Engineering, Biomedical

Wireless and battery-free technologies for neuroengineering

Sang Min Won et al.

Summary: This Review Article discusses recent progress in the development of miniaturized and ultralightweight devices for neuroengineering, which are wireless, battery-free, and fully implantable. These devices can restrict natural motions and prevent social interactions in animal models, limiting their utility in behavioural neuroscience research. However, advanced neural interfaces with optical, electrical, or fluidic functionality have emerged, capable of combining recording and stimulation modalities for closed-loop applications in basic studies or the treatment of abnormal physiological processes.

NATURE BIOMEDICAL ENGINEERING (2023)

Article Biophysics

Ultra-soft and highly stretchable tissue-adhesive hydrogel based multifunctional implantable sensor for monitoring of overactive bladder

Byungkook Oh et al.

Summary: A highly stretchable and tissue-adhesive multifunctional sensor has been developed for monitoring bladder activity in overactive bladder (OAB) induced rat and anesthetized pig. The sensor uses structurally engineered islets embedded in ultra-soft hydrogel, allowing firm attachment onto the bladder. It can detect bladder inflation and deflation through resistance changes, and electromyography (EMG) through Au electrodes coated with Platinum black.

BIOSENSORS & BIOELECTRONICS (2023)

Article Engineering, Biomedical

Scalable and modular wireless-network infrastructure for large-scale behavioural neuroscience

Raza Qazi et al.

Summary: This study presents a scalable and modular hardware and software infrastructure for remotely operating programmable miniaturized wireless networks to study the long-term behavior of large groups of rodents.

NATURE BIOMEDICAL ENGINEERING (2022)

Article Medicine, Research & Experimental

Exploration of High and Low Frequency Options for Subperception Spinal Cord Stimulation Using Neural Dosing Parameter Relationships: The HALO Study

Jose Paz-Solis et al.

Summary: This study explored the possibility of achieving effective subperception pain relief at lower frequencies, with adjustments made to the electrical and parameter relationships to achieve effectiveness surpassing previously thought necessary high-energy waveforms. By reducing frequency, energy savings were achieved to varying degrees, and the pain relief effect persisted for up to one year, with 85% of patients preferring frequencies below 400 Hz.

NEUROMODULATION (2022)

Article Biophysics

A fully implantable wireless bidirectional neuromodulation system for mice

Jason P. Wright et al.

Summary: Novel research in bioelectronic medicine requires a high-performance neuromodulation system for mice. This study presents a fully-implantable system that can record and stimulate neural activity in mice, with small size and weight. The system allows simultaneous readout of multiple physiological signals and complete control over stimulation parameters.

BIOSENSORS & BIOELECTRONICS (2022)

Article Chemistry, Multidisciplinary

A Subdural Bioelectronic Implant to Record Electrical Activity from the Spinal Cord in Freely Moving Rats

Bruce Harland et al.

Summary: This study presents the development of a very thin flexible bioelectronic implant that can be inserted directly into the spinal cord of rats and maintain contact. The implant does not negatively impact the functionality of the rats' limbs and can record electrical signals of spinal cord activity. This device is important for monitoring spinal cord injury and recovery, and has the potential for localized treatments.

ADVANCED SCIENCE (2022)

Article Multidisciplinary Sciences

Closed-loop direct control of seizure focus in a rodent model of temporal lobe epilepsy via localized electric fields applied sequentially

Wonok Kang et al.

Summary: Direct electrical stimulation of the seizure focus can terminate epileptic oscillations, but intervening the hippocampus is challenging. In this study, a sequential narrow-field stimulation method was used to terminate seizures in a rat model with spatially extensive hippocampal structure. The results demonstrate the selectiveness and preciseness of this method, suggesting its potential as a therapeutic approach.

NATURE COMMUNICATIONS (2022)

Article Engineering, Biomedical

A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies

Fangqi Liu et al.

Summary: This paper presents a fully implantable closed-loop device for investigating new treatments for motor neuron disease in freely moving rodents. The device features multiple stimulators and a neural recording front-end, and is powered by a wireless inductive link and a backup rechargeable battery. Control is achieved via a Bluetooth telemetry link. Measured results demonstrate the performance of the electronics and packaging method.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2022)

Article Biotechnology & Applied Microbiology

An Inductively Powered Implantable System to Study the Gastrointestinal Electrophysiology in Freely Behaving Rodents

Dylan T. Berry et al.

Summary: The development of an implantable system for studying the electrophysiology of the GI tract is crucial for understanding functional GI disorders and motility dysfunctions. This system allows monitoring and modulation of the bioelectrical activity of the gastric system in freely behaving rodents, providing insights into the relationship between GI disorders and gastric dysrhythmias and the potential of electroceutical therapies for motility dysfunctions in clinical settings.

BIOENGINEERING-BASEL (2022)

Article Medicine, Research & Experimental

Spinal Cord Stimulation Attenuates Below-Level Mechanical Hypersensitivity in Rats After Thoracic Spinal Cord Injury

Wanru Duan et al.

Summary: This study found that both conventional SCS and 1200 Hz, low-intensity SCS modestly attenuated below-level mechanical hypersensitivity in SCI rats. However, the inhibition of WDR neurons by conventional SCS was not associated with pain inhibition.

NEUROMODULATION (2021)

Article Energy & Fuels

A Wireless Power Transfer Based Implantable ECG Monitoring Device

Junho Kim et al.

ENERGIES (2020)

Review Biochemistry & Molecular Biology

Emerging Modalities and Implantable Technologies for Neuromodulation

Sang Min Won et al.

Article Engineering, Electrical & Electronic

Spirally Arrayed Electrode for Spatially Selective and Minimally Displacive Peripheral Nerve Interface

Ockchul Kim et al.

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS (2020)

Article Engineering, Biomedical

SenseBack-An Implantable System for Bidirectional Neural Interfacing

Ian Williams et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2020)

Article Multidisciplinary Sciences

Effective weight control via an implanted self-powered vagus nerve stimulation device

Guang Yao et al.

NATURE COMMUNICATIONS (2018)

Review Engineering, Electrical & Electronic

Review of polymer MEMS micromachining

Brian J. Kim et al.

JOURNAL OF MICROMECHANICS AND MICROENGINEERING (2016)

Article Engineering, Electrical & Electronic

Front-End Monitoring of Multiple Loads in Wireless Power Transfer Systems Without Wireless Communication Systems

Jian Yin et al.

IEEE TRANSACTIONS ON POWER ELECTRONICS (2016)

Article Health Care Sciences & Services

A burden of illness study for neuropathic pain in Europe

Hiltrud Liedgens et al.

CLINICOECONOMICS AND OUTCOMES RESEARCH (2016)

Article Clinical Neurology

Burst Spinal Cord Stimulation for Limb and Back Pain

Dirk De Ridder et al.

WORLD NEUROSURGERY (2013)

Article Engineering, Biomedical

Analysis of monophasic and biphasic electrical stimulation of nerve

JT Rubinstein et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2001)