4.5 Article

Permanent pacemaker implantation and left bundle branch block with self-expanding valves - a SCOPE 2 subanalysis

Journal

EUROINTERVENTION
Volume 18, Issue 13, Pages E1077-+

Publisher

EUROPA EDITION
DOI: 10.4244/EIJ-D-22-00558

Keywords

aortic stenosis; atrio-ventricular block; femoral

Ask authors/readers for more resources

The incidence and impact of new LBBB and PPI were assessed in a comparison of ACURATE neo and CoreValve Evolut devices. The study found that the ACURATE neo valve had lower rates of PPI and LBBB compared to the CoreValve Evolut valve. PPI at 30 days did not affect 1-year mortality, but LBBB at 30 days was associated with reduced ejection fraction at 1 year.
Background: No detailed data on left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) exist from randomised clinical trials comparing the ACURATE neo and CoreValve Evolut devices. Aims: Our aim was to assess the incidence and impact of new LBBB and PPI with self-expanding prostheses from a powered randomised comparison. Methods: From the SCOPE 2 trial, 648 patients with no previous pacemaker were analysed for PPI at 30 days, and 426 patients without previous LBBB were adopted for analysis of LBBB at 30 days. Results: At 30 days, 16.5% of patients required PPI; rates were higher in CoreValve Evolut compared to ACURATE neo recipients (21.0% vs 12.3%; p=0.004). Previous right bundle branch block (odds ratio [OR] 6.11, 95% confidence interval [CI]: 3.19-11.73; p < 0.001) was associated with an increased risk of PPI at 30 days, whereas the use of the ACURATE neo (OR 0.50, 95% CI: 0.31-0.81; p=0.005) was associated with a decreased risk. One-year mortality was similar in patients with and without new PPI. A total of 9.4% of patients developed persistent LBBB at 30 days, with higher incidences in CoreValve Evolut recipients (13.4% vs 5.5%; p=0.007). New LBBB at 30 days was associated with lower ejection fraction at 1 year (65.7%+/- 11.0 vs 69.1%+/- 7.6; p=0.041). Conclusions: New LBBB and PPI rates were lower in ACURATE neo compared to CoreValve Evolut recipients. The ACURATE neo valve was associated with a lower risk of PPI at 30 days. No effect on 1-year mortality was determined for PPI at 30 days, while LBBB at 30 days was associated with reduced ejection fraction at 1 year.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available