Decoupled Prediction Method for Water Pollutant Concentration Based on SPA-SVR Using Ultraviolet Spectroscopy

Journal

LASER & OPTOELECTRONICS PROGRESS
Volume 60, Issue 7, Pages -

Publisher

SHANGHAI INST OPTICS & FINE MECHANICS, CHINESE ACAD SCIENCE
DOI: 10.3788/LOP220700

Keywords

spectroscopy; ultraviolet spectrum; chemical oxygen demand; turibidity; coupling prediction; support vector regression

Ask authors/readers for more resources

A decoupling method was developed in this study using continuous projection algorithm and support vector regression to analyze and detect the concentration of multiple pollutants in complex water bodies. The test results showed that the method achieved high detection accuracy.
The rapid and accurate coupling interference analysis and concentration detection of the multiple pollutants in complex water bodies are significantly important for the in-situ real-time monitoring of field water quality. To address the problems of characteristic coupling and the interference of spectral peaks in the synchronous detection of chemical oxygen demand (COD) and turbidity using ultraviolet spectroscopy, which significantly affect the detection accuracy, a decoupling method for predicting water pollutant concentration was developed in this study based on the continuous projection algorithm combined with support vector regression. The continuous projection algorithm was used to screen the characteristic wavelengths of the ultraviolet absorption spectra of water quality samples and eliminate irrelevant redundant numbers, to improve the iteration rate and accuracy of the model. Based on the concept of the multi-classification support vector machine, the support vector regression algorithm was improved via multi-regression fitting, and the ultraviolet coupling analysis of COD and turbidity, as well as the simultaneous prediction of concentration, was realized. The test results for actual water samples reveal that the maximum relative errors are reduced to less than 4%, and the improvement rate of the root mean square error of predictions before the coupling analysis reaches 76%. Thus, the proposed method offers a better detection accuracy, as compared with similar methods. Notably, this work is expected to serve as a reference for the application of ultraviolet spectroscopy in water-quality multi-coupling parameter detection.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available