4.4 Article

Design of Cold-Formed Steel Built-Up Back-to-Back Columns Subject to Local-Flexural Interactive Buckling

Journal

JOURNAL OF STRUCTURAL ENGINEERING
Volume 149, Issue 12, Pages -

Publisher

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/JSENDH.STENG-12689

Keywords

Cold-formed steel; Built-up column; I-section; Effective width method; Direct strength method; Local-flexural interactive buckling

Ask authors/readers for more resources

This study evaluates the local-flexural interactive buckling of cold-formed steel built-up columns and proposes new design equations to accurately predict the ultimate load. The existing design guidelines are found to underestimate the local-flexural interactive buckling, and the effect of fastener spacing on this buckling mode is assessed. The study provides insights into the behavior of built-up columns and offers reliable design equations.
The North American Standard (NAS) and the European Standard (EC3) for cold-formed steel design provide limited guidelines for the strength predictions of built-up columns. The existing design equations are limited to flexural buckling and local-flexural interactive buckling. The present study evaluates the local-flexural interactive design equations for cold-formed steel built-up back-to-back I-section columns against the results of experimental and numerical studies. The results show that the existing design guidelines for local-flexural interactive buckling are unconservative by about 17%, 5%, and 15% for DSM-NAS, EWM-NAS, and EWM-EC3, respectively. Furthermore, a maximum reduction in the built-up column strength by local-flexural interaction is observed when its nominal local and flexural buckling loads are close. Based on the results and observations, new design equations are proposed by including the product of nominal local and flexural buckling loads for the North American and European standards, which capture the local-flexural interactive buckling in built-up I-section columns. The effect of fastener spacing on the ultimate load for local-flexural interactive buckling is also evaluated, and its effect is found to be small, unlike for global buckling. The minimum fastener spacing criteria of NAS are assessed, and suitable recommendations are provided for fixed-end columns. Overall, the present study provides insights into the local-flexural interactive buckling behavior of built-up I-section columns and proposes reliable design equations to predict the ultimate load.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available