4.6 Article

Validated green high performance liquid chromatographic and capillary electrophoretic methods for estimation of dinitolmide in presence of its acid-degradation product

Journal

SUSTAINABLE CHEMISTRY AND PHARMACY
Volume 36, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.scp.2023.101231

Keywords

Dinitolmide; HPLC; Capillary electrophoresis (CE); Diode-array detector; Greenness

Ask authors/readers for more resources

This study describes the development of two new, green, fast, specific, and highly sensitive stability-indicating techniques for the determination of Dinitolmide (DM) and its acid-induced degradation product. The methods showed good sensitivity and accuracy, and were successfully applied to pure and pharmaceutical dosage forms.
This study describes two new, green, fast, specific and highly sensitive stability-indicating tech-niques for determination of Dinitolmide (DM) in presence of its acid induced degradation product without prior separation; Acid degradation was carried out by hydrolysis with 0.1 N HCl; and the acidic degradation pathway was established by IR, and MS techniques. The first is a HPLC-Diode Array detector was performed by isocratic mode on BDS Hypersil C18 column (150 mm x 4.6 mm x 5 mu m particle size) at ambient temperature with a mobile phase consist-ing of 5 mM sodium acetate buffer (pH 5.5): acetonitrile (40:60, v/v), flow rate of 1 mL/min and detection at 210 nm. DM and its acid degradant were eluted at 4.3 and 2.8 min, respectively of-fering quick analysis. Linearity of the calibration curves confirm good correlation in range of 1-15 mu g/mL with recovery % of 100.02 +/- 0.460. The LOD and LOQ were 0.243 and 0.737, re-spectively. The second method is CE-Diode Array detector was carried out at 25 degrees C using borate buffer (30 mM, pH 9) as background electrolyte solution and detection at 225 nm. The migration times were 2.26 and 2.97 min for DM and its acid degradant, respectively. The linearity range was 5-50 mu g/mL with recovery % of 99.55 +/- 0.910, LOD and LOQ were 1.010 and 3.050, re-spectively. The small LOD and LOQ values for both methods confirm high sensitivity of the meth-ods The developed methods were validated according to the ICH guidelines demonstrating good accuracy and precision. The results were statistically compared with those obtained by a reported method in terms of accuracy, precision, and no significant difference was found. Both methods were successfully applied for estimating DM and its acid degradant in pure and pharmaceutical dosage forms. In addition, the methods were assessed for their greenness profile and CE was greener owing to using safer solvents and less energy consumption.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available