4.3 Article

The everolimus eluting Synergy Megatron™ drug-eluting stent platform: Early outcomes from the European Synergy Megatron™ Implanters' Registry

Journal

Publisher

WILEY
DOI: 10.1002/ccd.30902

Keywords

bifurcation; drug-eluting stent; left main

Ask authors/readers for more resources

This study reports the short- to medium-term clinical outcomes of using the Synergy Megatron (TM) everolimus-eluting stent for the treatment of coronary artery disease in a registry conducted at European centers. The results show favorable clinical outcomes at 30 days and 1 year.
Background: The Synergy Megatron (TM) is an everolimus-drug eluting stent that may offer advantages in the treatment of aorto-ostial disease and large proximal vessels.Aims: To report the short- to medium-term clinical outcomes from the European Synergy Megatron (TM) Implanters' Registry.Methods: This registry was an investigator-initiated study conducted at 14 European centers. The primary outcome was target lesion failure (TLF), defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularisation.Results: Five hundred seventy-five patients underwent PCI with Megatron (TM) between 2019 and 2021. Patients were 69 +/- 12 years old, 26% had diabetes mellitus, 24% had moderate-severe left ventricular impairment and 59% presented with an acute coronary syndrome. 15% were deemed prohibitively high risk for surgical revascularisation. The target vessel involved the left main stem in 55%, the ostium of the RCA in 13% and was a true bifurcation (Medina 1,1,1) in 50%. At 1 year, TLF was observed in 40 patients, with 26 (65%) occurring within the first 30 days. The cumulative incidence of TLF was 4.5% at 30 days and 8.6% (95% CI 6.3-11.7) at 1 year. The incidence of stent thrombosis was 0.5% with no late stent thromboses. By multivariate analysis, the strongest independent predictors of TLF were severe left ventricular impairment (HR 3.43, 95% CI: 1.67-6.76, p < 0.001) and a target vessel involving the left main (HR 4.00 95% CI 1.81-10.15 p = 0.001).Conclusions: Use of the Synergy Megatron (TM) everolimus eluting stent in a 'real-world' setting shows favorable outcomes at 30 days and 1 year.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available