4.5 Article

Three-dimensional multilayered fibrous constructs for wound healing applications

Journal

BIOMATERIALS SCIENCE
Volume 4, Issue 2, Pages 319-330

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c5bm00211g

Keywords

-

Funding

  1. Fundacao Calouste Gulbenkian
  2. Fundacao para a Ciencia e a Tecnologia (FCT) [UID/QUI/50006/2013, MIT-Pt/BS-CTRM/0051/2008, PTDC/EMETME/103375/2008, SFRH/BD/51188/2010]
  3. MIT-Portugal Program (Bioengineering Systems Focus Area) FEDER
  4. FSE
  5. U.S. Army Research Office [W911NF-07-D-0004]
  6. Sanofi-Aventis
  7. MIT Center for Biomedical Innovation
  8. NCI [2P30CA014051-39]
  9. NATIONAL CANCER INSTITUTE [P30CA014051] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Electrospun materials are promising scaffolds due to their light-weight, high surface-area and low-cost fabrication, however, such scaffolds are commonly obtained as ultrathin two-dimensional non-woven meshes, lacking on topographical specificity and surface side-dependent properties. Herein, it is reported the production of three-dimensional fibrous materials with an asymmetrical inner structure and engineered surfaces. The manufactured constructs evidence fibrous-based microsized conical protrusions [length: (10 +/- 3) x 10(2) mu m; width: (3.8 +/- 0.8) x 10(2) mu m] at their top side, with a median peak density of 73 peaks per cm(2), while their bottom side resembles to a non-woven mesh commonly observed in the fabrication of two-dimensional electrospun materials. Regarding their thickness (3.7 +/- 0.1 mm) and asymmetric fibrous inner architecture, such materials avoid external liquid absorption while promoting internal liquid uptake. Nevertheless, such constructs also observed the high porosity (89.9%) and surface area (1.44 m(2) g(-1)) characteristic of traditional electrospun mats. Spray layer-by-layer assembly is used to effectively coat the structurally complex materials, allowing to complementary tailor features such as water vapor transmission, swelling ratio and bioactive agent release. Tested as wound dressings, the novel constructs are capable of withstanding (11.0 +/- 0.3) x 10(4) kg m(-2) even after 14 days of hydration, while actively promote wound healing (90 +/- 0.5% of wound closure within 48 hours) although avoiding cell adhesion on the dressings for a painless removal.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available