4.7 Article

Dynamic electrocardiogram changes are a novel risk marker for sudden cardiac death

Journal

EUROPEAN HEART JOURNAL
Volume -, Issue -, Pages -

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/ehad770

Keywords

Sudden cardiac death; ECG; Risk prediction; Dynamic; General population

Ask authors/readers for more resources

This study investigates the importance and prevalence of dynamic electrocardiogram (ECG) remodeling in sudden cardiac death (SCD) and finds that dynamic ECG remodeling improves SCD risk prediction.
Background and Aims Electrocardiogram (ECG) abnormalities have been evaluated as static risk markers for sudden cardiac death (SCD), but the potential importance of dynamic ECG remodelling has not been investigated. In this study, the nature and prevalence of dynamic ECG remodelling were studied among individuals who eventually suffered SCD.Methods The study population was drawn from two prospective community-based SCD studies in Oregon (2002, discovery cohort) and California, USA (2015, validation cohort). For this present sub-study, 231 discovery cases (2015-17) and 203 validation cases (2015-21) with >= 2 archived pre-SCD ECGs were ascertained and were matched to 234 discovery and 203 validation controls based on age, sex, and duration between the ECGs. Dynamic ECG remodelling was measured as progression of a previously validated cumulative six-variable ECG electrical risk score.Results Oregon SCD cases displayed greater electrical risk score increase over time vs. controls [+1.06 (95% confidence interval +0.89 to +1.24) vs. -0.05 (-0.21 to +0.11); P < .001]. These findings were successfully replicated in California [+0.87 (+0.7 to +1.04) vs. -0.11 (-0.27 to 0.05); P < .001]. In multivariable models, abnormal dynamic ECG remodelling improved SCD prediction over baseline ECG, demographics, and clinical SCD risk factors in both Oregon [area under the receiver operating characteristic curve 0.770 (95% confidence interval 0.727-0.812) increased to area under the receiver operating characteristic curve 0.869 (95% confidence interval 0.837-0.902)] and California cohorts.Conclusions Dynamic ECG remodelling improved SCD risk prediction beyond clinical factors combined with the static ECG, with successful validation in a geographically distinct population. These findings introduce a novel concept of SCD dynamic risk and warrant further detailed investigation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available