4.4 Article

Generation of synthetic aortic valve stenosis geometries for in silico trials

Related references

Note: Only part of the references are listed.
Article Engineering, Biomedical

Fluid-structure interaction analysis of transcatheter aortic valve implantation

Ivan Fumagalli et al.

Summary: By analyzing fluid dynamics and structural indicators, it is possible to predict the potential deterioration of the prosthetic valve after TAVI. This can assist clinicians in decision-making and intervention design, without requiring additional peri-operative or follow-up information.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2023)

Article Biochemical Research Methods

Shape-driven deep neural networks for fast acquisition of aortic 3D pressure and velocity flow fields

Endrit Pajaziti et al.

Summary: This study explores the use of machine learning (ML) to improve the application of computational fluid dynamics (CFD) in clinical settings. By simulating 3000 CFD simulations on synthetically generated aortic shapes, the ML models were able to reproduce conventional CFD results much faster, with a processing time 4000 times faster than traditional methods, and with reasonable accuracy.

PLOS COMPUTATIONAL BIOLOGY (2023)

Article Cardiac & Cardiovascular Systems

Impact of tapered-shape left ventricular outflow tract on pacemaker rate after transcatheter aortic valve replacement

Kenichi Ishizu et al.

Summary: Mechanical compression of left ventricular outflow tract is a leading cause of permanent pacemaker implantation after transcatheter aortic valve replacement. This study found that tapered-shape LVOT, short Delta MSID, and pre-existing CRBBB were independently associated with PPI after TAVR.

HEART AND VESSELS (2022)

Article Engineering, Biomedical

Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements

David Oks et al.

Summary: This study used a computational model to analyze the impact of aortic annulus eccentricity and leaflet rigidity on bioprosthetic aortic valve replacements (BAVRs), highlighting their significant effects on valve performance, thrombogenic risk, and calcification risk.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2022)

Article Cardiac & Cardiovascular Systems

Computed Tomography-Based Assessment of Transvalvular Pressure Gradient in Aortic Stenosis

Benedikt Franke et al.

Summary: The study validated a method for assessing TPG in aortic stenosis using CT data, showing that there was no significant difference in TPG values between the CT method and catheter measurement method in 84 cases, with good consistency and correlation between the two methods.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2021)

Article Cardiac & Cardiovascular Systems

Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis

Flavien Vincent et al.

Summary: TAVR is rapidly expanding its indications, but faces technical challenges and knowledge gaps when dealing with patients with bicuspid aortic valve (BAV). Physicians need to understand the BAV anatomy and TAVR procedure planning comprehensively to guide treatment decisions.

CIRCULATION (2021)

Article Engineering, Biomedical

The impact of shape uncertainty on aortic-valve pressure-drop computations

M. J. M. M. Hoeijmakers et al.

Summary: Patient-specific image-based computational fluid dynamics (CFD) was used to segment aortic valves and study the impact of shape uncertainty on model output. Global variance-based sensitivity analysis revealed that shape uncertainty plays a significant role in CFD-computed transvalvular pressure-drops, with patient-specific sensitivity differences.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2021)

Article Physiology

Clinically-Driven Virtual Patient Cohorts Generation: An Application to Aorta

Pau Romero et al.

Summary: This paper discusses the generation of virtual patient cohorts through machine learning methods and simulation techniques, focusing on generating thoracic aorta geometry virtual patient cohorts that meet specific clinical criteria. The results show that generative adversarial networks can produce reliable, clinically-driven cohorts.

FRONTIERS IN PHYSIOLOGY (2021)

Article Materials Science, Multidisciplinary

Fluid-Structure Interaction in Problems of Patient Specific Transcatheter Aortic Valve Implantation with and Without Paravalvular Leakage Complication

Adi Azriff Basri et al.

Summary: The study utilized numerical simulation to analyze the impact of paravalvular leakage (PVL) on the performance of the patient's aorta. The results indicated that the presence of PVL can increase blood velocity, pressure drop, and wall shear stress, potentially leading to complications such as recirculation, thrombus formation, and aortic wall damage.

FDMP-FLUID DYNAMICS & MATERIALS PROCESSING (2021)

Article Mathematical & Computational Biology

Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case

Adi A. Basri et al.

COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE (2020)

Review Multidisciplinary Sciences

Creation and application of virtual patient cohorts of heart models

S. A. Niederer et al.

PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES (2020)

Article Engineering, Biomedical

Combining statistical shape modeling,CFD, and meta-modeling to approximate the patient-specific pressure-drop across the aortic valve in real-time

M. J. M. M. Hoeijmakers et al.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2020)

Article Cardiac & Cardiovascular Systems

On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach

Giulia Luraghi et al.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2019)

Article Cardiac & Cardiovascular Systems

Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing

Ahmed Hosny et al.

JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY (2019)

Article Computer Science, Interdisciplinary Applications

Nonparametric Inference for Multivariate Data: The R Package npmv

Amanda R. Ellis et al.

JOURNAL OF STATISTICAL SOFTWARE (2017)

Article Engineering, Biomedical

Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes

Alice Finotello et al.

MEDICAL ENGINEERING & PHYSICS (2017)

Review Engineering, Biomedical

In silico assessment of biomedical products: The conundrum of rare but not so rare events in two case studies

Marco Viceconti et al.

PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE (2017)

Article Cardiac & Cardiovascular Systems

Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement

Jose F. Condado et al.

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS (2017)

Letter Cardiac & Cardiovascular Systems

Patient-Specific Computer Modeling to Predict Aortic Regurgitation After Transcatheter Aortic Valve Replacement

Peter de Jaegere et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2016)

Article Biophysics

Simulations of transcatheter aortic valve implantation: implications for aortic root rupture

Qian Wang et al.

BIOMECHANICS AND MODELING IN MECHANOBIOLOGY (2015)

Article Cardiac & Cardiovascular Systems

Aortic Root Dimensions Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement

Lutz Buellesfeld et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2013)

Review Cardiac & Cardiovascular Systems

Coronary Obstruction Following Transcatheter Aortic Valve Implantation A Systematic Review

Henrique Barbosa Ribeiro et al.

JACC-CARDIOVASCULAR INTERVENTIONS (2013)

Article Cardiac & Cardiovascular Systems

Computational modelling of the right ventricle in repaired tetralogy of Fallot: can it provide insight into patient treatment?

Benedetta Leonardi et al.

EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING (2013)

Article Engineering, Biomedical

Influence of Bicuspid Valve Geometry on Ascending Aortic Fluid Dynamics: A Parametric Study

Christian Vergara et al.

ARTIFICIAL ORGANS (2012)

Article Cardiac & Cardiovascular Systems

Automated Assessment of the Aortic Root Dimensions With Multidetector Row Computed Tomography

Victoria Delgado et al.

ANNALS OF THORACIC SURGERY (2011)

Article Computer Science, Interdisciplinary Applications

A Statistical Model for Quantification and Prediction of Cardiac Remodelling: Application to Tetralogy of Fallot

T. Mansi et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2011)

Article Computer Science, Artificial Intelligence

Segmentation of the heart and great vessels in CT images using a model-based adaptation framework

Olivier Ecabert et al.

MEDICAL IMAGE ANALYSIS (2011)

Article Cardiac & Cardiovascular Systems

Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve Bioprosthesis

Mohammad A. Sherif et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2010)

Article Computer Science, Artificial Intelligence

Statistical models of sets of curves and surfaces based on currents

Stanley Durrleman et al.

MEDICAL IMAGE ANALYSIS (2009)

Review Computer Science, Artificial Intelligence

Statistical shape models for 3D medical image segmentation: A review

Tobias Heimann et al.

MEDICAL IMAGE ANALYSIS (2009)