4.6 Article

Ionophore-Based Polymeric Sensors for Potentiometric Assay of the Anticancer Drug Gemcitabine in Pharmaceutical Formulation: A Comparative Study

Journal

MOLECULES
Volume 28, Issue 22, Pages -

Publisher

MDPI
DOI: 10.3390/molecules28227552

Keywords

gemcitabine; ionophore; host-guest; PVC sensors; potentiometry; quality control

Ask authors/readers for more resources

In this study, three selective gemcitabine hydrochloride sensors were developed using cyclodextrins as ionophores. These sensors showed high selectivity and sensitivity for gemcitabine hydrochloride and had comparable accuracy and precision to the official method.
Gemcitabine is a chemotherapeutic agent used to treat various malignancies, including breast and bladder cancer. In the current study, three innovative selective gemcitabine hydrochloride sensors are developed using 4-tert-butylcalix-[8]-arene (sensor 1), beta-cyclodextrin (sensor 2), and gamma-cyclodextrin (sensor 3) as ionophores. The three sensors were prepared by incorporating the ionophores with o-nitrophenyl octyl ether as plasticizer and potassium tetrakis(4-chlorophenyl) borate as ionic additive into a polyvinyl chloride polymer matrix. These sensors are considered environmentally friendly systems in the analytical research. The linear responses of gemcitabine hydrochloride were in the concentration range of 6.0 x 10-6 to 1.0 x 10-2 mol L-1 and 9.0 x 10-6 to 1.0 x 10-2 mol L-1 and 8.0 x 10-6 to 1.0 x 10-2 mol L-1 for sensors 1, 2, and 3, respectively. Over the pH range of 6-9, fast-Nernst slopes of 52 +/- 0.6, 56 +/- 0.3, and 55 +/- 0.8 mV/decade were found in the same order with correlation regressions of 0.998, 0.999, and 0.998, respectively. The lower limits of detection for the prepared sensors were 2.5 x 10-6, 2.2 x 10-6, and 2.7 x 10-6 mol L-1. The sensors showed high selectivity and sensitivity for gemcitabine. Validation of the sensors was carried out in accordance with the requirements established by the IUPAC, while being inexpensive and easy to use in drug formulation. A statistical analysis of the methods in comparison with the official method showed that there was no significant difference in accuracy or precision between them. It was shown that the new sensors could selectively and accurately find gemcitabine hydrochloride in bulk powder, pharmaceutical formulations, and quality control tests. The ionophore-based sensor shows several advantages over conventional PVC membrane sensor sensors regrading the lower limit of detection, and higher selectivity towards the target ion.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available