4.4 Article

Optimizing Wearable Device and Testing Parameters to Monitor Running-Stride Long-Range Correlations for Fatigue Management in Field Settings

Publisher

HUMAN KINETICS PUBL INC
DOI: 10.1123/ijspp.2023-0186

Keywords

overtraining; biomechanics; motor control; accelerometer; sampling rate

Ask authors/readers for more resources

This study investigated the methodological considerations for translating wearable-based gait-monitoring data to field settings and used dynamical systems variables for athlete monitoring. The results showed that a 100 Hz sampling rate and signal lengths of 200 to 300 strides can be used to detect gait changes following intensive training. Additionally, using mean data from two sessions can lower the smallest detectable change values.
Purpose: There are important methodological considerations for translating wearable-based gait-monitoring data to field settings. This study investigated different devices' sampling rates, signal lengths, and testing frequencies for athlete monitoring using dynamical systems variables. Methods: Secondary analysis of previous wearables data (N = 10 runners) from a 5-week intensive training intervention investigated impacts of sampling rate (100-2000 Hz) and signal length (100-300 strides) on detection of gait changes caused by intensive training. Primary analysis of data from 13 separate runners during 1 week of field-based testing determined day-to-day stability of outcomes using single-session data and mean data from 2 sessions. Stride-interval long-range correlation coefficient alpha from detrended fluctuation analysis was the gait outcome variable. Results: Stride-interval alpha reduced at 100and 200- versus 300- to 2000-Hz sampling rates (mean difference: -.02 to -.08; P <= .045) and at 100- compared to 200- to 300-stride signal lengths (mean difference: -.05 to -.07; P < .010). Effects of intensive training were detected at 100, 200, and 400 to 2000 Hz (P <= .043) but not 300 Hz (P = .069). Within-athlete alpha variability was lower using 2-session mean versus single-session data (smallest detectable change: .13 and .22, respectively). Conclusions: Detecting altered gait following intensive training was possible using 200 to 300 strides and a 100-Hz sampling rate, although 100 and 200 Hz underestimated alpha compared to higher rates. Using 2-session mean data lowers smallest detectable change values by nearly half compared to single-session data. Coaches, runners, and researchers can use these findings to integrate wearable-device gait monitoring into practice using dynamic systems variables.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available