4.6 Article

Feasibility study for the adoption of multi-capsule irradiation protocol in the conduct of k0-based INAA using the GHARR-1 MNSR

Related references

Note: Only part of the references are listed.
Article Instruments & Instrumentation

Yield calculation for delayed gamma-ray neutron activation analysis

Tongyuan Cui et al.

Summary: A MATLAB-based code named CYANUS is developed to quantitatively evaluate the specific yields of delayed gamma-rays released from neutron irradiated objects in neutron activation analysis (NAA) applications. The comparison with other online programs shows that CYANUS provides the most accurate evaluation of specific gamma-ray yields, indicating its promising potential in NAA applications.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2023)

Review Nuclear Science & Technology

Neutronic calculations and thermalhydraulic application using CFD for the nuclear research reactor NUR at steady state mode

K. Sidi-Ali et al.

Summary: Neutronic calculations are performed for the X-1 configuration of NUR nuclear research reactor core, followed by a CFD thermalhydraulic modeling of the reactor core hot channel. The calculated power peaking factors are introduced into the power distribution equation which is applied to the outer area of the fuel meat. The obtained results confirm that Onset of Nucleate Boiling (ONB) and cladding melting cannot occur under the conditions of the present study.

PROGRESS IN NUCLEAR ENERGY (2023)

Article Chemistry, Physical

Measurement of neutron capture cross sections for the 174Yb(n,γ)175Yb reaction at thermal and epithermal energies

Nguyen Thi Hien et al.

Summary: In this study, the thermal neutron capture cross section and resonance integral of the 174Yb(n,γ)175Yb reaction were measured relative to the reference reaction 197Au(n,γ)198Au. The experiments were conducted using the activation method combined with Cd ratio method and offline gamma-ray spectrometry. The results were compared with the measured and evaluated data.

RADIATION PHYSICS AND CHEMISTRY (2023)

Article Nuclear Science & Technology

Neutron-induced damage simulations using MCNP6 and SRIM codes: Beyond neutron transmutation doping of silicon

Nadjet Osmani et al.

Summary: This study investigates the damage caused by neutron irradiation on silicon and the production of phosphorus in the irradiated samples. The resistance and surface morphology were found to increase with increasing Displacement per Atom (DPA) after neutron irradiation.

ANNALS OF NUCLEAR ENERGY (2023)

Article Chemistry, Inorganic & Nuclear

Performance of various mathematical functions for the in-situ relative detector efficiency towards its applicability for k0 IM-NAA

Manish Chand et al.

Summary: This study explores and compares various mathematical functions to establish the in-situ relative detector efficiency calibration for internal mono standard neutron activation analysis (IM-NAA), demonstrating its accuracy and feasibility through experiments.

APPLIED RADIATION AND ISOTOPES (2022)

Article Nuclear Science & Technology

Measurement of deuterium concentration in heavy water utilizing prompt gamma neutron activation analysis (PGNAA) in comparison with MCNPX simulation results

Saeed Salahi et al.

Summary: This study aims to measure deuterium concentration by calculating the area under the 2.23 MeV gamma-ray photo peak resulting from neutron collision with hydrogen atoms mixed with deuterium in samples. The study conducted simulation and experiment, showing high coordination results, and the accuracy was verified by comparing with Fourier transform infrared spectroscopy method.

NUCLEAR ENGINEERING AND TECHNOLOGY (2022)

Article Instruments & Instrumentation

Development and testing of a Delayed Gamma-ray Spectroscopy instrument utilizing Cf-252 neutrons evaluated for nuclear safeguards applications

Douglas Chase Rodriguez et al.

Summary: The collaboration between JAEA and EC/JRC on delayed gamma-ray spectroscopy has resulted in the development of the DGTS-C instrument for nuclear material accountancy. Experimental results confirm the practicality and effectiveness of this instrument design in enhancing safeguards capabilities.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Instruments & Instrumentation

Standardization and validation of k0-based Neutron Activation Analysis using Apsara-U reactor and its application to pure iron metal and coal sample for trace element determination

S. K. Samanta et al.

Summary: The k(0)-NAA method has been standardized for characterizing neutron flux in the reactor. The method has been validated for chemical characterization and elemental analysis, showing reliability in the results.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Instruments & Instrumentation

The low enriched uranium miniature neutron source reactor (LEU-MNSR) neutron spectrum characterization for k0-INAA

B. Osei et al.

Summary: The research reactor in Ghana has been converted from highly enriched uranium to low enriched uranium, resulting in a neutron spectrum that is relatively harder with a marginal increase in high-energy neutrons. The reactor's spectrum parameters were used to validate the k(0)-IAEA software, which showed suitable characterization process and general applicability. Analysis of certified reference materials using routine irradiation scheme demonstrated good quality assurance, with most elements within acceptable u-score limits.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2021)

Article Chemistry, Inorganic & Nuclear

Studies on neutron spectrum characterization for the Pneumatic Fast Transfer System (PFTS) of KAMINI reactor

G. V. S. Ashok Kumar et al.

APPLIED RADIATION AND ISOTOPES (2017)

Article Chemistry, Inorganic & Nuclear

Characterization of low power research reactor neutrons for the validation of k0-INAA standardization based on k0-IAEA software

I. K. Baidoo et al.

APPLIED RADIATION AND ISOTOPES (2013)

Article Chemistry, Analytical

How to calculate uncertainties of neutron flux parameters and uncertainties of analysis results in k0-NAA?

Marie Kubesova et al.

JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY (2012)

Article Instruments & Instrumentation

k0-NAA quality assessment in an Algerian laboratory by analysis of SMELS and four IAEA reference materials using Es-Salam research reactor

L. A. Hamidatou et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2012)

Article Instruments & Instrumentation

Determination of k0-factors of short-lived nuclides and application of k0-NAA to selected trace elements

R. Acharya et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2012)

Article Nuclear Science & Technology

Neutron flux determination in irradiation sites of an Am-Be neutron source at NNRI

E. Mensimah et al.

ANNALS OF NUCLEAR ENERGY (2011)

Article Instruments & Instrumentation

Comparison of Kayzero for Windows and k0-IAEA software packages for k0 standardization in neutron activation analysis

Marie Kubesova et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2011)

Article Instruments & Instrumentation

Analysis of SMELS and reference materials for validation of the k0-based internal monostandard NAA method using in-situ detection efficiency

R. Acharya et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2010)

Article Chemistry, Inorganic & Nuclear

Measurement of the fast neutron flux in the MNSR inner irradiation site

K. Khattab

APPLIED RADIATION AND ISOTOPES (2007)

Article Physics, Atomic, Molecular & Chemical

Recommended nuclear data for use in the k0 standardization of neutron activation analysis

F De Corte et al.

ATOMIC DATA AND NUCLEAR DATA TABLES (2003)

Article Instruments & Instrumentation

Measurement of thermal neutron cross-sections and resonance integrals for 71Ga(n, γ)72Ga and 75As(n, γ)76As by using 241Am-Be isotopic neutron source

M Karadag et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2003)

Article Chemistry, Analytical

Characterization of the Dalhousie University SLOWPOKE-2 reactor for k(0)-NAA and application to medium-lived nuclides

R Acharya et al.