4.7 Article

Shaking table test and numerical simulation of a precast frame-shear wall structure with innovative untopped precast concrete floors

Journal

ENGINEERING STRUCTURES
Volume 300, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2023.117162

Keywords

Shaking table test; Discretely connected precast concrete floor; Frame-shear wall structure; Seismic performance; In -plane stiffness; Numerical simulation

Ask authors/readers for more resources

This paper presents the seismic performance of a precast frame-shear wall structure adopting an innovative discretely connected precast concrete floor (DCPCF). The shaking table test and finite element modeling were conducted to evaluate the dynamic characteristics and seismic responses. The study provides design suggestions for multi-storey and high-rise buildings using DCPCF.
An innovative discretely connected precast concrete floor (DCPCF) was presented, in which the adjacent precast concrete hollow or sandwich flat slabs were connected by mechanical connectors embedded in the precast concrete slabs and beams. This paper summarized the seismic performance observed during the shaking table test of a precast frame-shear wall structure adopting DCPCF. A 1/4-scale model of a 4-storey 2-bay single-span frameshear wall structure was designed and tested on the shaking table to evaluate the dynamic characteristics and seismic responses of building structures adopting DCPCF. In addition, a finite element model, including detailed modeling of beam-column joint and slab joint connections, was established using nonlinear dynamic modeling program. The predictions on the seismic performance using the finite element model agreed well with the test results for the designed frame-shear wall structure. The precast concrete frame-shear wall structure adopting DCPCF had satisfactory seismic performance during the test process. The in-plane deformation of DCPCF was observed under the horizontal earthquakes, and DCPCF could not satisfy the requirements of rigid diaphragm assumption in most cases under design basis seismic intensity. The seismic design method based on semi-rigid floor diaphragm had large error and safety risk in calculating the seismic shear force of building structure adopting DCPCF. Additionally, design suggestions for multi-storey and high-rise building structures using DCPCF were proposed based on the observed seismic responses.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available