4.7 Review

Non-Invasive Cardiac Output Measurement Using Inert Gas Rebreathing Method during Cardiopulmonary Exercise Testing-A Systematic Review

Journal

JOURNAL OF CLINICAL MEDICINE
Volume 12, Issue 22, Pages -

Publisher

MDPI
DOI: 10.3390/jcm12227154

Keywords

aerobic performance; cardiopulmonary exercise test; cardiac output; non-invasive measurement of cardiac output; inert gas rebreathing

Ask authors/readers for more resources

This systematic review aims to describe the use of an inert gas rebreathing method for non-invasive cardiac output assessment during cardiopulmonary exercise testing and propose a CPET report that includes the assessment of cardiac output using this method. The review highlights the need for standardized approaches to CPET and identifies gaps in the current literature.
Background: The use of inert gas rebreathing for the non-invasive cardiac output measurement has produced measurements comparable to those obtained by various other methods. However, there are no guidelines for the inert gas rebreathing method during a cardiopulmonary exercise test (CPET). In addition, there is also a lack of specific standards for assessing the non-invasive measurement of cardiac output during CPET, both for healthy patients and those suffering from diseases and conditions. Aim: This systematic review aims to describe the use of IGR for a non-invasive assessment of cardiac output during cardiopulmonary exercise testing and, based on the information extracted, to identify a proposed CPET report that includes an assessment of the cardiac output using the IGR method. Methods: This systematic review was conducted by PRISMA (Preferred Reporting Items for Systematic Reviews and Meta Analyses) guidelines. PubMed, Web of Science, Scopus, and Cochrane Library databases were searched from inception until 29 December 2022. The primary search returned 261 articles, of which 47 studies met the inclusion criteria for this review. Results and Conclusions: This systematic review provides a comprehensive description of protocols, indications, technical details, and proposed reporting standards for a non-invasive cardiac output assessment using IGR during CPET. It highlights the need for standardized approaches to CPET and identifies gaps in the literature. The review critically analyzes the strengths and limitations of the studies included and offers recommendations for future research by proposing a combined report from CPET-IGR along with its clinical application.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available