4.6 Article

Comparison of automated subcutaneous defibrillator screening between different pacing sites in cardiac pacing device carriers

Journal

EUROPACE
Volume 25, Issue 12, Pages -

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/europace/euad352

Keywords

Conduction system pacing; Screening; Subcutaneous defibrillator; Left bundle pacing; His bundle pacing

Ask authors/readers for more resources

This study compared the screening results of S-ICD among different cardiac pacing sites and identified electrocardiographic predictors of success.
Aims The compatibility of cardiac pacing with the presence of a subcutaneous implantable cardioverter-defibrillator (S-ICD) has been investigated, but S-ICD screening test results have not been compared among different pacing sites. The objective was to compare S-ICD screening results among different cardiac pacing sites and to assess the electrocardiographic predictors of success.Methods and results This prospective single-centre study conducted automated S-ICD screening in 102 carriers of cardiac pacing devices in conduction system (CSP), biventricular (BVP), right ventricular outflow tract (RVOT), or right ventricular apex (RVA) pacing sites. The study included 102 patients: 40 with CSP (20 left bundle pacing and 20 His bundle pacing), 21 with BVP, and 20 and 21 with RVOT and RVA pacing, respectively. The percentage of positive screenings was significantly higher for CSP (97.5%) than for the other patient groups (BVP 71.4%, RVOT 70%, and RVA 19%). In multivariate analysis, positive screening was associated with a narrower QRS (OR 0.95 [0.92-0.98] P = 0.001) and higher R/T ratio in precordial leads (1.76 [1.18-2.61]).Conclusion A higher S-ICD eligibility rate of cardiac pacing device carriers was obtained in CSP than in conventional pacing (RVA or RVOT) or BVP. The presence of narrower paced QRS width and paced corrected QT interval and of higher R/T ratio in precordial and limb leads are electrocardiographic predictors of a positive response to screening. Graphical Abstract (A) Electrocardiographic predictors related to positive screening. (B) Multivariate logistic regression analysis with 'positive screening' as dependent variable. (C) Multivariate logistic regression analysis with 'positive screening' as dependent variable including 'pacing site' variable. **RV apex as reference value. OR, odds ratio; CSP, conduction system pacing; BVP, biventricular pacing; RVOT, right ventricular outflow tract; pQTc, paced corrected QT interval; R/Tp, T and R wave ratio in precordial leads; R/TL, T and R wave ratio in limb leads.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available