4.2 Article

Beyond forced exhalation: impulse oscillometry as a promising tool for bronchial hyperresponsiveness evaluation

Journal

JOURNAL OF ASTHMA
Volume -, Issue -, Pages -

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/02770903.2023.2288316

Keywords

IOS; oscillometry; pulmonary function tests; bronchial provocation test; methacholine test; bronchial hyperreactivity; asthma

Ask authors/readers for more resources

This study investigates the relationship between impulse oscillometry (IOS) and spirometry during the methacholine test and finds a good correlation between the two. IOS shows a strong predictive value in detecting bronchial hyperreactivity.
Introduction: The multiple forced expiratory maneuvers that must be performed during methacholine test require a high degree of collaboration and can lead to fatigue. However, impulse oscillometry (IOS) is a noninvasive test, quick and easy to perform, that does not require effort-dependent maneuvers.Objectives: The primary endpoint was to evaluate the relationship between IOS and spirometry during the methacholine test. The secondary endpoint was to study the predictive value of baseline IOS in the development of bronchial hyperreactivity.Methods: Observational, prospective, cross-sectional study, with recruitment of consecutive patients from the pulmonology department with clinical suspicion of bronchial asthma with negative bronchodilator test and normal FeNO.Results: Twenty-five patients were included, with a mean age of 49 +/- 18 years. Thirteen patients (52%) had a positive methacholine test. The correlation between IOS indices and FEV1 was significant (p < 0.05) in all cases. The indices with the highest predictive power were R5-20 and AX. The optimal cutoff points were an increase of greater than 32.96% in R5, greater than 120.83% for X5, an increase of 30.30 [kPa l-1s-1] in R5-20, and an increase of 1.01 [kPa l-1] for AX. Baseline oscillometry demonstrated a strong predictive value in the development of bronchial hyperreactivity, with a sensitivity of 61.5% and a specificity of 91.7%, using the cut-off point of 160.0% for R5.Conclusions: IOS may be a valuable alternative to forced spirometry in detecting bronchial hyperreactivity during the methacholine test, showing a good correlation between both tests.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available