4.4 Article

Partially depleted operation of 250 μm-thick silicon carbide neutron detectors

Related references

Note: Only part of the references are listed.
Article Instruments & Instrumentation

Performance of a thick 250?m silicon carbide detector: stability and energy resolution

M. H. Kushoro et al.

Summary: Silicon carbide detectors are tested as an alternative to diamond detectors for fast neutron detection in harsh environments. Thicker prototypes of 250 μm are evaluated for spectroscopy measurements, showing stable detection and potentially achieving the lowest energy resolution (1.3%) with SiC detectors. Difficulties in full depletion and prospects of partial polarization operation are highlighted.

JOURNAL OF INSTRUMENTATION (2023)

Article Chemistry, Analytical

Radiation Damage by Heavy Ions in Silicon and Silicon Carbide Detectors

Carmen Altana et al.

Summary: The radiation damage studies of a new large area p-n junction silicon carbide device developed by the SiCILIA collaboration are discussed in this work. The results show that the new devices exhibit excellent performance in terms of stability, linearity, defect distribution, charge collection efficiency, energy resolution, leakage current, etc., and have a radiation resistance more than two orders of magnitude higher than silicon devices. The application of the new construction technology to silicon carbide material has enabled the creation of robust devices with excellent performance.

SENSORS (2023)

Article Instruments & Instrumentation

A high-resolution neutron spectroscopic camera for the SPARC tokamak based on the Jet European Torus deuterium-tritium experience

M. Tardocchi et al.

Summary: This article discusses the assessment of nuclear diagnostics designed, developed, and built within EUROFUSION enhancement programs, focusing on the performance evaluation of high-resolution neutron spectrometers in 14 MeV DT Experiment campaign. The experience gained will be used for the concept of a spectroscopic neutron camera for the SPARC tokamak.

REVIEW OF SCIENTIFIC INSTRUMENTS (2022)

Article Chemistry, Physical

Detector Response to D-D Neutrons and Stability Measurements with 4H Silicon Carbide Detectors

Matteo Hakeem Kushoro et al.

Summary: The use of silicon carbide as a neutron detector shows promising potential for applications in environments requiring compact size and high radiation resistance. Experimental results demonstrate good stability and response function of silicon carbide detectors for 2-4 MeV neutrons, making them suitable for use in spallation neutron sources and fusion machines. Additionally, silicon carbide may serve as an interesting alternative to diamond detectors for fast neutron detection due to its lack of polarization effects during neutron and alpha irradiation.

MATERIALS (2021)

Article Chemistry, Physical

Epitaxial Growth and Characterization of 4H-SiC for Neutron Detection Applications

Alessandro Meli et al.

Summary: This work studied the properties of 4H-SiC epitaxial layers for neutron detection devices, comparing different growth rates and thicknesses and their effects on carrier lifetime through optical and Raman spectroscopy.

MATERIALS (2021)

Article Instruments & Instrumentation

High rate neutron and gamma ray spectroscopy of magnetic confinement fusion plasmas

M. Tardocchi et al.

JOURNAL OF INSTRUMENTATION (2020)

Article Instruments & Instrumentation

Silicon Carbide characterization at the n_TOF spallation source with quasi-monoenergetic fast neutrons

M. H. Kushoro et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2020)

Article Instruments & Instrumentation

New thick silicon carbide detectors: Response to 14 MeV neutrons and comparison with single-crystal diamonds

M. Rebai et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2019)

Article Instruments & Instrumentation

Response function of single crystal synthetic diamond detectors to 1-4 MeV neutrons for spectroscopy of D plasmas

M. Rebai et al.

REVIEW OF SCIENTIFIC INSTRUMENTS (2016)

Article Instruments & Instrumentation

Neutron emission spectroscopy of DT plasmas at enhanced energy resolution with diamond detectors

L. Giacomelli et al.

REVIEW OF SCIENTIFIC INSTRUMENTS (2016)

Article Instruments & Instrumentation

First neutron spectroscopy measurements with a pixelated diamond detector at JET

A. Muraro et al.

REVIEW OF SCIENTIFIC INSTRUMENTS (2016)

Article Nuclear Science & Technology

Solid state detectors for neutron radiation monitoring in fusion facilities

J. M. Gomez-Ros

RADIATION MEASUREMENTS (2014)

Review Physics, Applied

Mechanisms of growth and defect properties of epitaxial SiC

F. La Via et al.

APPLIED PHYSICS REVIEWS (2014)

Article Physics, Fluids & Plasmas

Fusion neutron flux monitor for ITER

Yang Jinwei et al.

PLASMA SCIENCE & TECHNOLOGY (2008)

Article Physics, Applied

Richardson's constant in inhomogeneous silicon carbide Schottky contacts

F Roccaforte et al.

JOURNAL OF APPLIED PHYSICS (2003)

Article Engineering, Electrical & Electronic

Schottky-ohmic transition in nickel silicide/SiC-4H system: is it really a solved problem?

F La Via et al.

MICROELECTRONIC ENGINEERING (2003)