4.4 Article

The effect of geometrical parameters of skin brachytherapy patch source on depth dose distribution using Monte Carlo simulation

Journal

APPLIED RADIATION AND ISOTOPES
Volume 204, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2023.111117

Keywords

Skin cancer brachytherapy; Cylindrical beta-emitting patch source; Geometrical parameters; Depth dose distribution; Monte Carlo simulation

Ask authors/readers for more resources

This study investigated the effect of patch source geometric parameters on the depth dose distribution in skin tissue through Monte Carlo simulation. The results showed that increasing the source-to-skin distance, patch thickness, and patch diameter will reduce the depth dose distribution, with the source-to-skin distance having the most significant impact on dose gradient.
Brachytherapy of superficial skin tumors using beta-emitting sources is a method that has been investigated by some researchers in both simulation and experimental studies with promising results. In the current study, the effect of geometrical parameters of some relevant radionuclides including Y-90, Re-188, P-32, and Ho-166 on the depth dose distribution in skin tissue has been investigated through Monte Carlo simulation. MCNPX Monte Carlo code was employed to model the above-mentioned patch sources in cylindrical format and then the effect of patch geometrical parameters including the source-to-skin distance (SSD), patch thickness, and patch diameter on depth dose distribution was assessed through modeling and calculation of the dose inside a cubic phantom mimicking the skin tissue. The obtained results demonstrated that increasing the SSD, patch thickness, and patch diameter (with the same activity) will reduce the depth dose distribution. Changing the SSD has a more significant effect on the dose gradient within the depth than other geometrical parameters. It was also observed that the effect of patch diameter on the skin-delivered dose gets less sensible as the patch size goes beyond the range of beta radiation inside tissue. Finally, it can be concluded that the patch source geometrical parameters can affect the depth dose distribution inside the skin tissue. This fact may be of concern regarding the delivery of a high radiation dose in a single treatment session. Therefore, variations of patch source geometrical parameters should be considered during the skin dose calculation plan.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available