4.1 Article

Evaluation of larval surface antigens from infective larvae of Strongyloides venezuelensis for the serodiagnosis of human strongyloidiasis

Publisher

INST MEDICINA TROPICAL SAO PAULO
DOI: 10.1590/S1678-9946202365001

Keywords

Strongyloidiasis; Strongyloides venezuelensis; Surface; Enzyme-linked; immunosorbent assay; Serodiagnosis

Ask authors/readers for more resources

The study aimed to evaluate the diagnostic accuracy of surface cuticle antigens of infective larvae of S. venezuelensis extracted with CTAB detergent (L3-CTAB) compared to soluble somatic extracts (L3-SSE) in immunocompetent and immunocompromised individuals. The results showed that using L3-CTAB as an antigenic source in ELISA, the seropositivity rate in immunocompromised patients was 28.13%, while it was 34.38% when using L3-SSE. Therefore, L3-CTAB is simple, practical, and highly sensitive and specific.
Serodiagnosis of strongyloidiasis is usually performed by ELISA for the detection of IgG antibodies due to its high sensitivity and practicality, but its main limitation is a constant source of S. stercoralis antigens. The use of S. venezuelensis as a heterologous source of antigens has facilitated several published studies on the serodiagnosis and epidemiology of human strongyloidiasis. The main objective of this study was to evaluate the diagnostic accuracy of surface cuticle antigens of infective larvae of S. venezuelensis extracted with CTAB detergent (L3-CTAB) in comparison with soluble somatic extracts (L3-SSE) using a panel of sera from immunocompetent and immunocompromised individuals, at three different cut-offs. ROC curve analysis showed that L3-CTAB had an AUC of 0.9926. At the first cut-off value (OD 450 nm = 0.214), sensitivity and specificity were 100% and 90.11%, respectively, with a diagnostic accuracy of 0.93. At a second cut-off value (OD 450 nm = 0.286), sensitivity and specificity were 70% and 100%, respectively, with a diagnostic accuracy of 0.91. However, at an alternative third cut-off value (OD 450 nm = 0.589), sensitivity and specificity were 95% and 97.8%, respectively, with a diagnostic accuracy of 0.97. Using L3-CTAB as an antigenic source, the seropositivity rate in immunocompromised patients was 28.13% (9/32) whereas a seropositivity rate of 34.38% (11/32) was found when L3-SSE was used in ELISA. Therefore, the L3-CTAB is simple and practical to obtain and was found to be highly sensitive and specific.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available