4.6 Article

Bayesian Optimization Framework for HVAC System Control

Journal

BUILDINGS
Volume 13, Issue 2, Pages -

Publisher

MDPI
DOI: 10.3390/buildings13020314

Keywords

HVAC control; energy efficiency; contexture Bayesian optimization

Ask authors/readers for more resources

The use of machine-learning algorithms for optimizing HVAC energy efficiency has been extensively studied. Previous research focused on data-driven model predictive controls and reinforcement learning, but these approaches were not efficient and stable enough for practical applications. This paper proposes a Bayesian optimization framework for HVAC control that achieves near-optimal control performance, high efficiency, and stability for large-scale applications.
The use of machine-learning algorithms in optimizing the energy efficiency of HVAC systems has been widely studied in recent years. Previous research has focused mainly on data-driven model predictive controls and reinforcement learning. Both approaches require a large amount of online interactive data; therefore, they are not efficient and stable enough for large-scale practical applications. In this paper, a Bayesian optimization framework for HVAC control has been proposed to achieve near-optimal control performance while also maintaining high efficiency and stability, which would allow it to be implemented in a large number of projects to obtain large-scale benefits. The proposed framework includes the following: (1) a method for modeling HVAC control problems as contexture Bayesian optimization problems and a technology for automatically constructing Bayesian optimization samples, which are based on time series raw trending data; (2) a Gaussian process regression surrogate model for the objective function of optimization; (3) a Bayesian optimization control loop, optimized for the characteristics of HVAC system controls, including an additional exploration trick based on noise estimation and a mechanism to ensure constraint satisfaction. The performance of the proposed framework was evaluated by using a simulation system, which was calibrated by using trending data from a real data center. The results of our study showed that the proposed approach achieved more than a 10% increase in energy-efficiency savings within a few weeks of optimization time compared with the original building automation control.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available