3.9 Article

My preferred approach to left bundle branch pacing: Lumenless leads

Related references

Note: Only part of the references are listed.
Article Cardiac & Cardiovascular Systems

Electrophysiological characteristics of septal perforation during left bundle branch pacing

Shunmuga Sundaram Ponnusamy et al.

Summary: This study aimed to analyze the morphology of intracardiac electrograms and unipolar pacing parameters to identify septal perforation in patients undergoing Left Bundle Branch Pacing (LBBP). The results showed that septal perforation, when recognized promptly during implantation by unipolar parameters and treated by reimplantation, would be benign and not associated with an unfavorable outcome.

HEART RHYTHM (2022)

Article Cardiac & Cardiovascular Systems

A Guide to Left Bundle Branch Area Pacing Using Stylet-Driven Pacing Leads

Jan De Pooter et al.

Summary: Left bundle branch area pacing (LBBAP) is a novel pacing modality that captures the left bundle branch area and avoids the negative effects of right ventricular pacing. Standard stylet-driven pacing leads (SDL) can be used for LBBAP, but the implant technique differs from lumen-less pacing leads (LLL).

FRONTIERS IN CARDIOVASCULAR MEDICINE (2022)

Article Cardiac & Cardiovascular Systems

Current of injury is an indicator of lead depth and performance during left bundle branch pacing lead implantation

Shalaimaiti Shali et al.

Summary: The study aimed to evaluate the predictive value of current of injury on inadequate left bundle branch capture threshold and acute septal perforation. The results demonstrated that current of injury can predict the depth of left bundle branch pacing lead and the occurrence of septal perforation.

HEART RHYTHM (2022)

Article Cardiac & Cardiovascular Systems

Use of extendable helix leads for conduction system pacing: Differences in lead handling and performance lead design impacts conduction system pacing

Eugene S. J. Tan et al.

Summary: This study evaluated the handling characteristics and performance of extendable-retractable helix (EHL) leads compared to fixed-helix leads (FHL) in conduction system pacing (CSP). The results showed that EHL leads had a higher incidence of helix deformation and fracture compared to FHL leads, raising concerns about their long-term extractability in CSP.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2022)

Article Cardiac & Cardiovascular Systems

Initial experience of left bundle branch area pacing using stylet-driven pacing leads: A multicenter study

Jan De Pooter et al.

Summary: This registry study explores the safety and feasibility of left bundle branch area pacing (LBBAP) using stylet-driven leads (SDL) with extendable helix design. The results show that SDL-LBBAP is safe and feasible, with high implant success, low complication rates, and stable low pacing thresholds in a multicenter patient population.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2022)

Letter Cardiac & Cardiovascular Systems

Predictors of loss of capture in left bundle branch pacing: A multicenter experience

Eugene S. J. Tan et al.

HEART RHYTHM (2022)

Article Cardiac & Cardiovascular Systems

M-beat-A novel marker for selective left bundle branch capture

Shunmuga Sundaram Ponnusamy et al.

Summary: This study investigates the incidence and clinical significance of a unique morphology template beat called M-beat in PVC-guided LBBP. The results show that M-beat can predict selective LBB capture with high specificity and positive predictive value.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2022)

Article

Evaluation of Criteria for Left Bundle Branch Capture

Shunmuga Sundaram Ponnusamy et al.

Cardiac Electrophysiology Clinics (2022)

Article Cardiac & Cardiovascular Systems

Left bundle branch area pacing outcomes: the multicentre European MELOS study

Marek Jastrzebski et al.

Summary: Left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. This study evaluated the safety and feasibility of LBBAP and found that the success rate and safety in heart failure patients need to be improved.

EUROPEAN HEART JOURNAL (2022)

Article Cardiac & Cardiovascular Systems

Left bundle area pacing: Guiding implant depth by ring measurements

Michael Orlov et al.

Summary: This study investigated the measurement parameters of the lead ring in left bundle area pacing (LBAP) and found that ring impedance, lead-septal angle, and lead depth are related to lead progress, whereas tip impedance and septal thickness are not.

HEART RHYTHM (2022)

Article Cardiac & Cardiovascular Systems

Mid-term feasibility, safety and outcomes of left bundle branch pacing-single center experience

Shunmuga Sundaram Ponnusamy et al.

Summary: Left bundle branch pacing (LBBP) has a 94% acute success rate in the Indian population, effectively improving left ventricular ejection fraction, and serves as a safe and efficient physiological pacing strategy.

JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study

Lan Su et al.

Summary: Left bundle branch pacing (LBBP) showed high success rates and low complication rates in a large population of patients, leading to decreased QRS duration, improved left ventricular function, and reduced severity of tricuspid regurgitation.

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Fixation beats: A novel marker for reaching the left bundle branch area during deep septal lead implantation

Marek Jastrzebski et al.

Summary: This study found that monitoring fixation beats during deep septal lead deployment in LBB pacing device implantation can improve the safety of the procedure. Fixation beats, characterized by the appearance of qR/rsR' morphology in lead V-1, were observed to indicate whether the desired lead depth had been reached.

HEART RHYTHM (2021)

Article Cardiac & Cardiovascular Systems

Cardiac troponin release following left bundle branch pacing

Shunumuga S. Ponnusamy et al.

Summary: The study found that LBBP implantation is associated with myocardial injury, but the extent of injury is lower or comparable to other interventional electrophysiology procedures. Patients requiring more than 2 attempts for LBBP are more likely to experience significant elevation of troponin levels.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2021)

Letter Cardiac & Cardiovascular Systems

Template Beat A Novel Marker for Left Bundle Branch Capture During Physiological Pacing

Shunmuga Sundaram Ponnusamy et al.

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Repositioning and extraction of stylet-driven pacing leads with extendable helix used for left bundle branch area pacing

Jean-Benoit le Polain de Waroux et al.

Summary: For left bundle branch area pacing, conventional stylet-driven leads with extendable helix can be successfully implanted with low acute complication rate, but there is a risk of helix fracture and failure to fully extract the pacing lead during lead repositioning.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2021)

Article Cardiac & Cardiovascular Systems

Case Report: Interventricular Septal Hematoma Complicating Left Bundle Branch Pacing Lead Implantation

Rujie Zheng et al.

Summary: A case of interventricular septal hematoma complicating LBBP lead implantation was reported. The hematoma was identified and resolved with urgent coronary angiography and echocardiography, respectively. Pacing parameters and cardiac function remained stable during the 6-month follow-up.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2021)

Article Cardiac & Cardiovascular Systems

Late dislodgement of left bundle branch pacing lead and successful extraction

Shunmuga Sundaram Ponnusamy et al.

Summary: A 61-year-old male underwent left bundle branch pacing for nonischemic dilated cardiomyopathy, resulting in improvement in LVEF initially but recurrence of symptoms and decline in LVEF two years later due to late lead dislodgement. After re-do LBBP with new lead placement, postprocedure echocardiography showed no complications.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2021)

Review Cardiac & Cardiovascular Systems

Left bundle branch pacing: A comprehensive review

Shunmuga Sundaram Ponnusamy et al.

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY (2020)

Article Cardiac & Cardiovascular Systems

Extraction of the permanent His bundle pacing lead: Safety outcomes and feasibility of reimplantation

Pugazhendhi Vijayaraman et al.

HEART RHYTHM (2019)

Article Cardiac & Cardiovascular Systems

Clinical Outcomes of His Bundle Pacing Compared to Right Ventricular Pacing

Mohamed Abdelrahman et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2018)

Review Cardiac & Cardiovascular Systems

His Bundle Pacing

Pugazhendhi Vijayaraman et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2018)