4.1 Article

Effect of Sodium Hypochlorite and Hypochlorous Acid Solutions on the Cyclic Fatigue Resistance of Waveonegold, K3XF and Hyflex-EDM: A Study of Metallurgical Properties

Journal

STRENGTH OF MATERIALS
Volume -, Issue -, Pages 191-204

Publisher

SPRINGER
DOI: 10.1007/s11223-023-00513-8

Keywords

dynamic model; cyclic fatigue test; hypochlorous acid; nickel-titanium instrument; sodium hypochlorite

Ask authors/readers for more resources

This study focused on investigating the effects of sodium-hypochlorite and hypochlorous-acid solutions on the cyclic fatigue resistance of three nickel-titanium instruments. It was found that the use of 2.5% sodium-hypochlorite and hypochlorous-acid solutions reduced the fracture resistance of one of the instruments, but had no significant effect on the other two. Hypochlorous-acid solution can be considered as an alternative irrigation solution due to its lower corrosiveness compared to sodium-hypochlorite solution.
The presented work was focused on investigating the effects of sodium-hypochlorite (NaOCl) and hypochlorous-acid (HOCl) solutions on the dynamic cyclic fatigue resistance of WaveOneGold (WOG), K3XF and Hyflex-EDM (HEDM) nickel-titanium (Ni-Ti) instruments. A total of 141 Ni-Ti instruments were included in the study, 45 of each file for cyclic fatigue testing and two for metallurgical analysis. The NiTi instruments were rotated in an artificial canal that was immersed in three different solutions [2.5% NaOCl, HOCl or distilled water (DW)] at body temperature until fracture occurred and the time to fracture (TtF) in seconds was recorded. Fractured and unused files were analysed by scanning-electron-microscopy (SEM) with energy-dispersive X-ray spectrometry (EDS), X-ray diffraction (XRD), and a microhardness tester. The mean data were analyzed statistically using Kruskal-Wallis, and post hoc Mann-Whitney-U test. The TtF of the HEDM was statistically significantly higher than that of WOG and K3XF for all solutions. It was found that 2.5% NaOCl and HOCl solutions reduced the TtF of the WOG, but had no significant effect on the K3XF and HEDM. By EDS analysis, it was determined that titanium-oxide compounds were formed on the file surfaces at most in 2.5% NaOCl solution. The highest hardness value was K3XF, and the lowest hardness value belonged to the HEDM instrument. The HOCl solution can be used as an alternative irrigation solution as it is less corrosive to the instruments compared to than NaOCl solution.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available