4.6 Article

A cascade amplification strategy based on rolling circle amplification and hybridization chain reaction for ultrasensitive detection of pathogens

Journal

ANALYTICAL METHODS
Volume 15, Issue 19, Pages 2382-2390

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/d3ay00440f

Keywords

-

Ask authors/readers for more resources

Rapid and accurate detection of pathogens is crucial for the prevention, control, and diagnosis of infectious diseases. In this study, an ultrasensitive nucleic acid isothermal cascade amplification technique combining rolling circle amplification (RCA) and hybridization chain reaction (HCR) was developed for the detection of ORF1ab in SARS-CoV-2. The proposed method showed a detection limit as low as 7.65 fM and demonstrated satisfactory recoveries in serum samples. This facile and ultrasensitive assay provides a promising tool for ORF1ab analysis and can be applied to the detection of various pathogens and genetic biomarkers.
Rapid and accurate detection of a variety of pathogens is very important for the prevention, control, and diagnosis of infectious diseases. Herein, an ultrasensitive nucleic acid isothermal cascade amplification technique based on rolling circle amplification (RCA) coupled with hybridization chain reaction (HCR) was developed for ORF1ab (opening reading frame 1a/b) for SARS-CoV-2 detection. In this scheme, the ORF1ab sequence hybridized with a padlock probe to trigger RCA reaction. Specifically, the recognition site for a unique nicking enzyme was incorporated into the padlock probe to cut the RCA products into short intermediate amplicons, which contain dual HCR initiation sites and can be directly used as primers for HCR. HCR probes, H1 and H2, labeled with FAM (FAM-H1 and FAM-H2) spontaneously participated in the HCR and formed a long nicked dsDNA. Additional probes were quenched by graphene oxide (GO) via pi-stacking to decrease the background signal. Meanwhile, the fluorescence signal can be strongly amplified by the synergistic effect of FAM and SYBR green I. The proposed RCA-HCR method can be used to detect ORF1ab at concentrations as low as 7.65 fM. Moreover, the reliability of the RCA-HCR method in serum samples has also been validated. Satisfactory recoveries ranging from 85% to 113% for ORF1ab can be obtained. Therefore, this facile and ultrasensitive RCA-HCR assay provides a new promising tool for ORF1ab analysis and can be extended to the detection of various kinds of pathogens and genetic biomarkers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available