4.6 Article

Dual imaging agent for magnetic particle imaging and computed tomography

Related references

Note: Only part of the references are listed.
Article Radiology, Nuclear Medicine & Medical Imaging

Contrast thresholds for detection of various iodine concentrations in subtraction CT and dual-energy CT systems

Anahita Heshmat et al.

Summary: This study aimed to determine the minimum detectable iodine concentrations in simulated vessels of different diameters using CT technology. The results showed that for the SCT system, the minimum detectable iodine concentration was 0.4 mg/ml in the 5-mm vessel, while for the DECT system, it was 1 mg/ml. The 3-mm vessel had a minimum detectable iodine concentration of 0.8 mg/ml (SCT) and 2 mg/ml (DECT). Finally, the minimum detectable iodine concentration for the 1-mm vessel was 10 mg/ml for both SCT and DECT systems. Overall, the SCT system had a higher iodine detection capability compared to the DECT system, and the iodine concentration requirements varied for vessels of different diameters.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2023)

Article Materials Science, Multidisciplinary

Particle motion artifacts in equilibrium magnetization measurements of large iron oxide nanoparticles

Shehaab Savliwala et al.

Summary: Iron oxide nanoparticles have various applications due to their response to external magnetic fields. Equilibrium magnetization measurements, also known as magnetization curves, are important for determining magnetic properties. This paper investigates the influence of sample preparation methods on magnetization data obtained from iron oxide nanoparticles. The results show that measurements in powder form and in liquid solvents have varying degrees of particle interaction artifacts at low fields, while measurements in waxy hydrocarbon matrices and hard crosslinked polymer matrices have different effects on particle motion.

JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS (2022)

Article Multidisciplinary Sciences

Fast nanoparticle rotational and translational diffusion in synovial fluid and hyaluronic acid solutions

Mythreyi Unni et al.

Summary: The diffusion behavior of polymer-coated inorganic nanoparticles in synovial fluid can be well described by the Stokes-Einstein relationship, with an effective medium viscosity much smaller than the macroscopic low shear viscosity of the fluid. The additional viscous dissipation in the effective medium viscosity is attributed to the presence of polymer segments, shedding light on the diffusive behavior of these nanoparticles in complex and crowded biological environments such as the joint.

SCIENCE ADVANCES (2021)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Principles and applications of multienergy CT: Report of AAPM Task Group 291

Cynthia H. McCollough et al.

MEDICAL PHYSICS (2020)

Article Multidisciplinary Sciences

Magnetic Particle Imaging meets Computed Tomography: first simultaneous imaging

Patrick Vogel et al.

SCIENTIFIC REPORTS (2019)

Review Clinical Neurology

A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging

L. C. Wu et al.

AMERICAN JOURNAL OF NEURORADIOLOGY (2019)

Article Pharmacology & Pharmacy

Theranostic nanocarriers combining high drug loading and magnetic particle imaging

Eric G. Fuller et al.

INTERNATIONAL JOURNAL OF PHARMACEUTICS (2019)

Review Radiology, Nuclear Medicine & Medical Imaging

A perspective on a rapid and radiation-free tracer imaging modality, magnetic particle imaging, with promise for clinical translation

Prashant Chandrasekharan et al.

BRITISH JOURNAL OF RADIOLOGY (2018)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Improving Spatial Resolution at CT: Development, Benefits, and Pitfalls

Jia Wang et al.

RADIOLOGY (2018)

Article Chemistry, Multidisciplinary

Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection

Elaine Y. Yu et al.

NANO LETTERS (2017)

Article Engineering, Biomedical

Combining magnetic particle imaging and magnetic fluid hyperthermia in a theranostic platform

Daniel Hensley et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Engineering, Biomedical

Single-Step Assembly of Multimodal Imaging Nanocarriers: MRI and Long-Wavelength Fluorescence Imaging

Nathalie M. Pinkerton et al.

ADVANCED HEALTHCARE MATERIALS (2015)

News Item Chemistry, Multidisciplinary

X-Space MPI: Magnetic Nanoparticles for Safe Medical Imaging

Patrick William Goodwill et al.

ADVANCED MATERIALS (2012)

Article Biochemical Research Methods

Fiji: an open-source platform for biological-image analysis

Johannes Schindelin et al.

NATURE METHODS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Tristan Nowak et al.

MEDICAL PHYSICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

EMI and the First CT Scanner

Riley E. Alexander et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Gold nanoparticles: a new X-ray contrast agent

JF Hainfeld et al.

BRITISH JOURNAL OF RADIOLOGY (2006)

Article Multidisciplinary Sciences

Tomographic imaging using the nonlinear response of magnetic particles

B Gleich et al.

NATURE (2005)