4.7 Article

Closed-Loop Control of a Multifunctional Myoelectric Prosthesis With Full-State Anatomically Congruent Electrotactile Feedback

Related references

Note: Only part of the references are listed.
Article Rehabilitation

Current rates of prosthetic usage in upper-limb amputees - have innovations had an impact on device acceptance?

Stefan Salminger et al.

Summary: This study collected data through a questionnaire survey on 68 traumatic upper limb amputees treated within the Austrian Trauma Insurance Agency from 1996 to 2016. It found a high rate of prosthesis abandonment in the upper extremity and no significant effect of recent advancements in prosthetic technology on acceptance.

DISABILITY AND REHABILITATION (2022)

Article Robotics

Object Recognition via Evoked Sensory Feedback during Control of a Prosthetic Hand

Luis Vargas et al.

Summary: This study evaluated the recognition of object properties using myoelectric control and sensory feedback in controlling a prosthetic hand. The findings show that evoked haptic and proprioceptive feedback can facilitate closed-loop control of the prosthetic hand, allowing for simultaneous recognition of different object properties.

IEEE ROBOTICS AND AUTOMATION LETTERS (2022)

Article Neurosciences

Toward improving control performance of myoelectric arm prosthesis by adding wrist position feedback

Yue Zheng et al.

Summary: Wearing a myoelectric prosthesis is a basic way for limb amputees to restore their lost limb functions. However, the lack of appropriate sensory feedback in current prostheses has led to a high refusal rate among amputees. This study designed a myoelectric arm prosthesis with wrist position feedback and demonstrated the importance of wrist position feedback for effective control of the prosthesis through experiments.

FRONTIERS IN HUMAN NEUROSCIENCE (2022)

Article Engineering, Biomedical

Estimating speed-accuracy trade-offs to evaluate and understand closed-loop prosthesis interfaces

Pranav Mamidanna et al.

Summary: This study evaluated and compared the performance of two closed-loop user-prosthesis interfaces using the framework of speed-accuracy trade-off functions (SAF). The results showed that the performance of closed-loop prosthesis interfaces depends on the feedback approach and execution speed, with electromyography (EMG) feedback performing better at medium speeds. The study also demonstrated the usefulness of the SAF framework in revealing differences between feedback approaches.

JOURNAL OF NEURAL ENGINEERING (2022)

Article Neurosciences

EMG feedback outperforms force feedback in the presence of prosthesis control disturbance

Jack Tchimino et al.

Summary: Closing the prosthesis control loop with artificial somatosensory feedback can enhance the functionality and user experience. This study compares the performance of EMG and force feedback in the presence of control disturbances and finds that EMG feedback outperforms force feedback in terms of reaction to disturbance and completion time.

FRONTIERS IN NEUROSCIENCE (2022)

Article Chemistry, Multidisciplinary

The Impact of Stimulation Intensity on Spatial Discrimination with Multi-Pad Finger Electrode

Jovana Malesevic et al.

Summary: The study achieved sensation localization through multi-pad electrotactile stimulation, showing that spatial discrimination is robust to changes in stimulation intensity, suitable for practical applications of a multi-pad electrotactile interface.

APPLIED SCIENCES-BASEL (2021)

Article Engineering, Biomedical

The impact of objective functions on control policies in closed-loop control of grasping force with a myoelectric prosthesis

Pranav Mamidanna et al.

Summary: This study explores how different task objectives shape the control policy developed by participants in a prosthesis force-matching task. Participants successfully integrated supplemental prosthesis force feedback to develop both feedforward and feedback control policies, as demanded by the task objectives. Training protocols that encourage the development of combined feedforward and feedback policy are found to be beneficial for prosthesis users.

JOURNAL OF NEURAL ENGINEERING (2021)

Article Engineering, Biomedical

The effect of calibration parameters on the control of a myoelectric hand prosthesis using EMG feedback

Jack Tchimino et al.

Summary: This study investigated the impact of cutoff frequency and normalization value on the quality of closed-loop control with EMG feedback. The experiments showed that lower cutoff frequency and higher normalization value resulted in better control performance for EMG feedback, with the optimal combination being 40% MVC and 0.5 Hz cutoff frequency.

JOURNAL OF NEURAL ENGINEERING (2021)

Article Engineering, Biomedical

A compact system for simultaneous stimulation and recording for closed-loop myoelectric control

Martin A. Garenfeld et al.

Summary: The study proposed a novel compact solution for simultaneous recording and stimulation through dynamic blanking of stimulation artefacts. By developing a feedback coding scheme specifically for myoelectric control, it was found that the quality of closed-loop control was preserved in spite of electrotactile stimulation.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2021)

Article Robotics

Neurorobotic fusion of prosthetic touch, kinesthesia, and movement in bionic upper limbs promotes intrinsic brain behaviors

Paul D. Marasco et al.

Summary: Research shows that integrating touch, grip kinesthesia, and intuitive motor control through a neurorobotic fusion can improve behavioral performance levels for bionic prosthesis users, achieving more human-like function. Sensory-motor restoration enhances balanced decision strategies and error correction performance during object interactions.

SCIENCE ROBOTICS (2021)

Article Engineering, Biomedical

Getting a Grip on the Impact of Incidental Feedback From Body-Powered and Myoelectric Prostheses

Michael A. Gonzalez et al.

Summary: The study found that participants using body-powered prostheses were more accurate in matching grasp apertures compared to those using myoelectric prostheses, while myoelectric prostheses users performed better in identifying virtual object stiffness.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2021)

Article Neurosciences

Mechanotactile Sensory Feedback Improves Embodiment of a Prosthetic Hand During Active Use

Ahmed W. Shehata et al.

FRONTIERS IN NEUROSCIENCE (2020)

Review Neurosciences

A Review of Sensory Feedback in Upper-Limb Prostheses From the Perspective of Human Motor Control

Jonathon W. Sensinger et al.

FRONTIERS IN NEUROSCIENCE (2020)

Article Engineering, Biomedical

Amplitude versus spatially modulated electrotactile feedback for myoelectric control of two degrees of freedom

Martin A. Garenfeld et al.

JOURNAL OF NEURAL ENGINEERING (2020)

Article Engineering, Biomedical

Evaluation of a Simultaneous Myoelectric Control Strategy for a Multi-DoF Transradial Prosthesis

Cristina Piazza et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2020)

Article Multidisciplinary Sciences

Neural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses

Enzo Mastinu et al.

SCIENTIFIC REPORTS (2020)

Review Engineering, Biomedical

Restoration of sensory information via bionic hands

Sliman J. Bensmaia et al.

NATURE BIOMEDICAL ENGINEERING (2020)

Article Computer Science, Cybernetics

Dual-Parameter Modulation Improves Stimulus Localization in Multichannel Electrotactile Stimulation

Lucia Seminara et al.

IEEE TRANSACTIONS ON HAPTICS (2020)

Article Engineering, Biomedical

Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand

Francesco Clemente et al.

JOURNAL OF NEURAL ENGINEERING (2019)

Article Neurosciences

Examining the Spatiotemporal Disruption to Gaze When Using a Myoelectric Prosthetic Hand

J. V. V. Parr et al.

JOURNAL OF MOTOR BEHAVIOR (2018)

Review Computer Science, Information Systems

A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands

Benjamin Stephens-Fripp et al.

IEEE ACCESS (2018)

Article Engineering, Biomedical

Myocontrol is closed-loop control: incidental feedback is sufficient for scaling the prosthesis force in routine grasping

Marko Markovic et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2018)

Proceedings Paper Computer Science, Artificial Intelligence

Evaluating Mapping Designs for Conveying Data through Tactons

Jamie Ferguson et al.

NORDICHI'18: PROCEEDINGS OF THE 10TH NORDIC CONFERENCE ON HUMAN-COMPUTER INTERACTION (2018)

Article Engineering, Biomedical

Short- and Long-Term Learning of Feedforward Control of a Myoelectric Prosthesis with Sensory Feedback by Amputees

Matija Strbac et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2017)

Article Engineering, Biomedical

Multichannel Electrotactile Feedback With Spatial and Mixed Coding for Closed-Loop Control of Grasping Force in Hand Prostheses

Strahinja Dosen et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2017)

Article Engineering, Biomedical

Multichannel electrotactile feedback for simultaneous and proportional myoelectric control

Gauravkumar K. Patel et al.

JOURNAL OF NEURAL ENGINEERING (2016)

Article Engineering, Biomedical

Integrated and flexible multichannel interface for electrotactile stimulation

Matija Strbac et al.

JOURNAL OF NEURAL ENGINEERING (2016)

Review Neurosciences

Literature Review on Needs of Upper Limb Prosthesis Users

Francesca Cordella et al.

FRONTIERS IN NEUROSCIENCE (2016)

Article Engineering, Biomedical

An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback

Jeremy D. Brown et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2015)

Article Engineering, Biomedical

Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques

Susannah M. Engdahl et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2015)

Article Orthopedics

Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users

Heidi J. B. Witteveen et al.

PROSTHETICS AND ORTHOTICS INTERNATIONAL (2015)

Article Engineering, Biomedical

Closed-Loop Control of Grasping With a Myoelectric Hand Prosthesis: Which Are the Relevant Feedback Variables for Force Control?

Andrei Ninu et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2014)

Article Engineering, Biomedical

Stiffness Feedback for Myoelectric Forearm Prostheses Using Vibrotactile Stimulation

Heidi J. B. Witteveen et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2014)

Article Engineering, Biomedical

Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control

J. M. Hahne et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2014)

Article Engineering, Biomedical

Visuomotor behaviours when using a myoelectric prosthesis

Mohammad M. D. Sobuh et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2014)

Article Engineering, Biomedical

A comparison of the real-time controllability of pattern recognition to conventional myoelectric control for discrete and simultaneous movements

Aaron J. Young et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2014)

Article Engineering, Biomedical

Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses

Heidi J. B. Witteveen et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2012)

Review Engineering, Biomedical

Control of Upper Limb Prostheses: Terminology and Proportional Myoelectric Control-A Review

Anders Fougner et al.

IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING (2012)

Article Engineering, Biomedical

The role of feed-forward and feedback processes for closed-loop prosthesis control

Ian Saunders et al.

JOURNAL OF NEUROENGINEERING AND REHABILITATION (2011)

Article Rehabilitation

Myoelectric forearm prostheses: State of the art from a user-centered perspective

Bart Peerdeman et al.

JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT (2011)

Article Orthopedics

Upper limb prosthesis use and abandonment: A survey of the last 25 years

Elaine A. Biddiss et al.

PROSTHETICS AND ORTHOTICS INTERNATIONAL (2007)

Article Engineering, Biomedical

A robust, real-time control scheme for multifunction myoelectric control

K Englehart et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2003)