4.6 Article

A BIM-Based Algorithm for Quantitative Monitoring of Temperature Distribution During Breast Hyperthermia Treatments

Journal

IEEE ACCESS
Volume 11, Issue -, Pages 38680-38695

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2023.3253482

Keywords

Microwave imaging; Monitoring; Temperature sensors; Hyperthermia; Temperature measurement; Breast cancer; Biomedical imaging; Breast imaging; hyperthermia; electromagnetic inverse scattering; microwave imaging; temperature monitoring

Ask authors/readers for more resources

Microwave hyperthermia (MH) treatment is a promising method for breast cancer, which can induce cell necrosis in malignant tumor or enhance the effect of chemotherapy. This paper presents an iterative differential microwave imaging algorithm for temperature monitoring based on Born iterative method (BIM) and Tikhonov regularization. The algorithm's feasibility is demonstrated through a large computational study using realistic digital breast phantoms. The results show that the proposed approach provides high resolution temperature estimation with low reconstruction error.
Microwave hyperthermia (MH) treatment for breast cancer is a research interest due to its capability to initiate cell necrosis in malignant tumor or to enhance the effect of other treatment modalities such as chemotherapy. The goal of MH treatment is to increase temperature of malignant tumor up to 45 degrees C based on the treatment plan; however, microwave energy focusing is a challenging problem and may cause unwanted hotspots on healthy tissues; therefore, there is a need to monitor the temperature. In this paper, an iterative differential microwave imaging algorithm for temperature monitoring is presented. The algorithm is based on Born iterative method (BIM) and Tikhonov regularization. Feasibility of the algorithm is shown by a large computational study using realistic digital breast phantoms via TMz polarized 2-D scattered fields. Also, some results are given for calibrated scattering parameters, which are obtained from both a 3-D electromagnetic simulation program and a simple measurement setup. An approach for selection of matching medium in hyperthermia monitoring applications is also presented. The reconstructions are performed with scattered field data collected at 11 discrete frequency points uniformly taken from the 0.5-1.5 GHz range. For a specific heating scenario in 2-D problem, reconstruction error is lower than 0.3% with +/- 10% noise on reference dielectric property distribution and 40 dB signal to noise ratio (SNR). The results show that the proposed approach provides up to 3. C and 0.1.C resolution in temperature estimation with +/- 10% noise on reference dielectric property distribution for 30 dB and 60 dB SNR values, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available