4.7 Article

An experimental study on effects of interventional stent treatment on hemodynamics in elastic aneurysms

Related references

Note: Only part of the references are listed.
Article Mechanics

TEVP model predictions of the pulsatile blood flow in 3D aneurysmal geometries

Konstantinos Giannokostas et al.

Summary: In recent years, significant progress has been made in hemorheological modeling with the development of constitutive models that can represent the physical mechanisms of blood cell and plasma interaction. This study focuses on pulsatile blood flow in 3D rigid aneurysmal geometries to better understand hemodynamics and biological processes. The results show that pulse frequency affects the flow structure, leading to recirculation in the aneurysmal dome. Increased pulse amplitude makes blood flow more easily, but with low wall shear stress inside the aneurysm, which may contribute to growth or rupture. The curvature of the parent vessel affects the flow dynamics, with higher total stress compared to straight vessels.

JOURNAL OF NON-NEWTONIAN FLUID MECHANICS (2023)

Article Cardiac & Cardiovascular Systems

Case Report: Dynamic Changes in Hemodynamics During the Formation and Progression of Intracranial Aneurysms

Xiaodong Zhai et al.

Summary: Despite the devastating consequences of aneurysmal subarachnoid hemorrhage (SAH), the mechanisms underlying the formation, progression, and rupture of intracranial aneurysms (IAs) are complex and not yet fully clear. By studying two real patients and using computational fluid dynamics simulation (CFD), this study provides insights into the dynamic process of IA development and the hemodynamic characteristics associated with it.

FRONTIERS IN CARDIOVASCULAR MEDICINE (2022)

Article Neurosciences

Outcomes after Flow Diverter Treatment in Subarachnoid Hemorrhage: A Meta-Analysis and Development of a Clinical Prediction Model (OUTFLOW)

Michelle F. M. Ten Brinck et al.

Summary: This study conducted a meta-analysis and developed a prediction model to estimate the favorable clinical outcome after flow diverter (FD) treatment for complex acutely ruptured intracranial aneurysms (IAs). The pooled rates showed high favorable clinical outcomes and aneurysm occlusion, but low quality of evidence was observed in all studies. The prediction model requires validation through larger prospective studies before clinical application.

BRAIN SCIENCES (2022)

Article Mechanics

Influence of morphological parameters on hemodynamics in internal carotid artery bifurcation aneurysms

Mahesh S. Nagargoje et al.

Summary: Recent advancements in medical imaging techniques have enabled accurate identification of unruptured intracranial aneurysms. Suitable mathematical models for rupture prediction are important for patient management. This study investigates the influence of morphological parameters on aneurysm hemodynamics and rupture prediction, finding correlations between these parameters and hemodynamic parameters.

PHYSICS OF FLUIDS (2022)

Article Mechanics

Hemodynamic characteristics in a cerebral aneurysm model using non-Newtonian blood analogues

Hang Yi et al.

Summary: This study aims to develop and validate a computational fluid dynamics (CFD) model to estimate hemodynamic characteristics in cerebral aneurysms (CAs) using non-Newtonian blood analogues. The study successfully measured blood viscosities under varying shear rates and temperatures, and developed a non-Newtonian viscosity model based on the measured data. The CFD model showed good agreement with experimental results in quantifying flow characteristics, and the non-Newtonian model accurately predicted blood shear-thinning properties. Results also indicated the importance of using non-Newtonian models in hemodynamic assessment of CAs.

PHYSICS OF FLUIDS (2022)

Review Clinical Neurology

Outcome of Flow Diverters with Surface Modifications in Treatment of Cerebral Aneurysms: Systematic Review and Meta-analysis

Y-L Li et al.

Summary: Based on a systematic review and meta-analysis, surface-modified flow diverters show good safety and efficacy in treating patients with cerebral aneurysms, with high technical success and aneurysm occlusion rates, as well as relatively low mortality and serious ischemia rates.

AMERICAN JOURNAL OF NEURORADIOLOGY (2021)

Article Chemistry, Physical

Advanced Constitutive Modeling of the Thixotropic Elasto-Visco-Plastic Behavior of Blood: Steady-State Blood Flow in Microtubes

Konstantinos Giannokostas et al.

Summary: This study focuses on the in-silico investigation of steady-state blood flow in straight microtubes, incorporating advanced constitutive modeling for human blood and blood plasma. The research demonstrates the microstructural configuration of blood in steady-state conditions, revealing highly aggregated blood in narrow tubes, and the extension of plasmatic proteins in the flow direction at high pressure-gradients generating large axial normal stresses. Predictions of normal stress at both the blood/plasma interface and the tube wall show significant differences in magnitude and type of variation, with INS linearly decreasing from 4.5 to 2 Pa and WNS exponentially decreasing from 50 mPa to zero with decreasing tube radius.

MATERIALS (2021)

Article Cardiac & Cardiovascular Systems

A Brush-Spin-Coating Method for Fabricating In Vitro Patient-Specific Vascular Models by Coupling 3D-Printing

Qing-Zhuo Chi et al.

Summary: An improved method combining 3D printing and brush-spin-coating processes was developed to produce patient-specific flexible vascular models of uniform or varied thickness. This method allows for the manufacturing of models with prescribed thickness, useful for developing surgical treatment strategies or training neuroendovascular interventionalists.

CARDIOVASCULAR ENGINEERING AND TECHNOLOGY (2021)

Article Engineering, Biomedical

In VitroAssessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV

Rafael Medero et al.

ANNALS OF BIOMEDICAL ENGINEERING (2020)

Proceedings Paper Engineering, Biomedical

Use of 3D printed intracranial aneurysm phantoms to test the effect of flow diverters geometry on hemodynamics

Ariana B. Allman et al.

MEDICAL IMAGING 2020: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS (2020)

Article Engineering, Biomedical

Non-Newtonian versus numerical rheology: Practical impact of shear-thinning on the prediction of stable and unstable flows in intracranial aneurysms

M. O. Khan et al.

INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING (2017)

Article Engineering, Mechanical

Pulsatile flow in a compliant stenosed asymmetric model

Abdullah Y. Usmani et al.

EXPERIMENTS IN FLUIDS (2016)

Article Health Care Sciences & Services

Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids

S. V. Frolov et al.

TECHNOLOGY AND HEALTH CARE (2016)

Article Neuroimaging

Effect of aneurysm and ICA morphology on hemodynamics before and after flow diverter treatment

Ignacio Larrabide et al.

JOURNAL OF NEUROINTERVENTIONAL SURGERY (2015)

Article Clinical Neurology

Roles of Hypertension in the Rupture of Intracranial Aneurysms

Yoshiteru Tada et al.

STROKE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Wall Shear Stress Estimated With Phase Contrast MRI in an In Vitro and In Vivo Intracranial Aneurysm

Pim van Ooij et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2013)