Early vascular responses to abluminal biodegradable polymer-coated versus circumferential durable polymer- coated newer-generation drug-eluting stents in humans: a pathological study

Journal

EUROINTERVENTION
Volume 18, Issue 15, Pages 1284-+

Publisher

EUROPA EDITION
DOI: 10.4244/EIJ-D-22-00650

Keywords

autopsy; drug-eluting stents; pathology

Ask authors/readers for more resources

This study evaluated the early pathologic responses to two different types of drug-eluting stents in human autopsy cases. The results showed that the stent with a biodegradable polymer coating had better coverage compared to the stent with a durable polymer coating. However, vessel healing was still suboptimal in both stents at 30 days.
Background: Recent clinical studies are testing strategies for short (1-3 months) dual antiplatelet therapy following newer-generation drug-eluting stent (DES) placement. However, detailed biological responses to newer-generation DES remain unknown in humans.Aims: We sought to evaluate early pathologic responses to abluminal biodegradable polymer-coated (BP-) DES compared with circumferential durable polymer-coated (DP-) DES in human autopsy cases.Methods: The study included 38 coronary lesions with newer-generation DES implanted for <90 days (DP-DES=24, BP-DES=14) in 26 autopsy cases. The degree of strut coverage was defined as follows: grade 0 (bare), grade 1 (with fibrin or tissues/cells without endothelium), grade 2 (with single-layered endothe-lium), and grade 3 (with endothelium and underlying smooth muscle cell layers).Results: The duration following implantation was similar in DP-and BP-DES (median=20 vs 17 days). A total of 2,022 struts (DP-DES=1,297, BP-DES=725) were pathologically analysed. Focal grade 2 cov-erage was observed as early as 5 days after the implantation in both stents. The multilevel mixed-effects ordered logistic regression model demonstrated that BP-DES exhibited greater strut coverage compared with DP-DES (odds ratio [OR]: 3.64, 95% confidence interval [CI]: 1.37-9.67; p=0.009), which remained significant after adjustment for the duration following implantation and underlying tissue characteristics (OR: 2.74, 95% CI: 1.10-6.80; p=0.030). The predictive probability of grade 2 and 3 coverage was com-parably limited at 30 days (DP-DES=17.1%, BP-DES=28.7%) and increased at 90 days (DP-DES=76.5%, BP-DES=86.6%). Both stents showed low inflammation and a similar degree of fibrin deposition.Conclusions: Single-layered endothelial coverage begins in the days after newer-generation DES place-ment, and BP-DES potentially exhibit faster strut coverage with smooth muscle cell infiltration than DP-DES in humans. Nevertheless, vessel healing remains suboptimal in both stents at 30 days.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available