3.8 Article

Utility of 3D T1-weighted turbo spin echo black blood sequence for the diagnosis of cerebral venous thrombosis

Journal

EMERGENCY RADIOLOGY
Volume 30, Issue 4, Pages 443-451

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s10140-023-02150-9

Keywords

CVT; CVST; Cortical venous; Deep venous; Dural sinus thrombosis; MRV; SWI; Post contrast T1 MPRAGE; 3D T1 SPACE; CUBE; VISTA; 3D T1 TSE

Ask authors/readers for more resources

This study evaluated the accuracy of 3D-T1 turbo spin echo (T1S) sequences in detecting venous thrombosis and compared it with other conventional sequences. The results showed that T1S demonstrated similar accuracy to conventional sequences in overall detection of CVT, but showed superior accuracy in detecting cortical venous thrombosis.
PurposeAccurate assessment of dural sinus, deep and cortical venous thrombosis on MR imaging is challenging. The aim of this study is to evaluate the accuracy of 3D-T1 turbo spin echo (T1S), sequences in detecting venous thrombosis and comparing it with susceptibility-weighted imaging (SWI), magnetic resonance venography (MRV) and post contrast T1 magnetization-prepared rapid acquisition gradient echo (T1C).MethodsA blinded retrospective observational analysis of 71 consecutive patients evaluated for cerebral venous thrombosis (CVT) and 30 control patients was performed. Multimodality reference standard adopted included T1C, SWI with MRV. Sub-analyses in superficial, deep and cortical venous segments were performed in addition to correlation of signal intensity of thrombus with the clinical stage.ResultsA total of 2222 segments in 101 complete MRI examinations were evaluated. Sensitivity/specificity/positive predictive value/negative predictive value/accuracy and precision of T1S for detection of cortical vein thrombosis was 0.994/1/1/0.967/0.995/1, 1/0.874/0.949/1/0.963/0.950 for detection of superficial venous sinus thrombosis and 1/1/1/1/1/1 for deep venous thrombosis. The AUC yield for T1S was 0.997 for cortical, 1 for deep and 0.988 for superficial venous segments.ConclusionT1S paralleled the accuracy of conventional sequences in the overall detection of CVT but showed superior accuracy in the detection of cortical venous thrombosis. It makes a fitting addition to the CVT MRI protocol in scenarios demanding negation of gadolinium administration.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available