4.4 Article

Pilot study on a new endoscopic platform for colorectal endoscopic submucosal dissection

Journal

THERAPEUTIC ADVANCES IN GASTROENTEROLOGY
Volume 16, Issue -, Pages -

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/17562848221104953

Keywords

colorectal cancer; endoscopy; ESD; hindgut; innovation; mini-invasive

Ask authors/readers for more resources

This study evaluated a new endoscopic platform called tissue retractor system (TRS) for use in endoscopic submucosal dissection (ESD). The results showed that TRS-assisted ESD is feasible and effective in the rectum, but there are still some technical limitations that need to be addressed.
Background: The endoscopic submucosal dissection (ESD) is a technically demanding and time-consuming procedure, with an increased risk of adverse events compared to standard endoscopic resection techniques. The main difficulties are related to the instability of the operating field and to the loss of traction. We aimed to evaluate in a pilot trial a new endoscopic platform [tissue retractor system (TRS); ORISE, Boston scientific Co., Marlborough, MA, USA], designed to stabilize the intraluminal space, and to provide tissue retraction and counter traction. Method: We prospectively enrolled all consecutive patients who underwent an ESD for sigmoid/rectal lesions. The primary outcome was the rate of technical feasibility. Further technical aspects such as en-bloc and R0 resection rate, number of graspers used, circumferential incision time, TRS assemblage time, submucosal dissection time, and submucosal dissection speed were provided. Clinical outcomes (recurrence rate and adverse events) were recorded as well. Results: In all, 10 patients (M/F 4/6, age: 70.4 +/- 11.0 years old) were enrolled. Eight out of 10 lesions were located in the rectum. Average lesion size was 31.2 +/- 2.7 mm, and mean lesion area was 1628.88 +/- 205.3 mm(2). The two sigmoid lesions were removed through standard ESD, because the platform assemblage failed after several attempts. All rectal lesions were removed in an en-bloc fashion. R0 resection was achieved in 7/8 (87.5%) patients in an average procedure time of 60.5 +/- 23.3 min. None of the patients developed neither intraprocedural nor postprocedural adverse events. Conclusion: TRS-assisted ESD is a feasible option when used in the rectum, with promising result in terms of efficacy and safety outcomes. Nevertheless, our pilot study underlines few technical limitations of the present platform that need to be overcome before the system could be widely and routinely used.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available