4.0 Article

Normative Spectral Domain Optical Coherence Tomography Data in Healthy Turkish Children

Journal

SEMINARS IN OPHTHALMOLOGY
Volume 32, Issue 2, Pages 216-222

Publisher

TAYLOR & FRANCIS INC
DOI: 10.3109/08820538.2015.1053625

Keywords

Central macular thickness; Cirrus HD-OCT; normative database; pediatric OCT; retinal nerve fiber layer

Categories

Ask authors/readers for more resources

Purpose: To determine the normative database of macular and retinal nerve fiber layer (RNFL) thickness parameters in healthy Turkish children by OCT. Methods: 318 eyes of 318 children (138 boys, 183 girls) aged between 3 and 17 years were evaluated. The children were scanned by Cirrus HD-OCT (Carl Zeiss Meditec) to measure the macula, RNFL, and optic nerve head parameters. Results: Axial length (AL) (p <0.001, R-2 = 0.08), spherical equivalent (SE) (p < 0.001, R-2 = 0.12), and rim area (p <0.001, R-2 = 0.15) were the strongest predictors of RNFL thickness. All of the macular measurements were significantly related to age (p <0.001, R-2 > 5%). Average macular thickness (p < 0.01) and outer macula (p = 0.002) showed significant relationship with the AL and SE. Conclusion: This study ensures an age-adjusted pediatric normative database using OCT to diagnose and monitor macular diseases, optic nerve diseases, and glaucoma in children.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available