4.2 Article

A Handheld Hydraulic Soft Robotic Device With Bidirectional Bending End-Effector for Minimally Invasive Surgery

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMRB.2023.3291014

Keywords

Soft robotics; soft guidewire; soft catheter; soft robotic arm; bidirectional bending; ablation; thrombus removal

Ask authors/readers for more resources

Minimally invasive surgery has been effective for cardiovascular diseases and gastrointestinal cancers. Soft robotic catheters using soft materials have gained attention for their ability to navigate complex anatomical structures. However, current systems have limitations due to rigid mechanisms and insufficient forces. New soft robotic catheters with bidirectional bending motion and spiral shapes have been introduced to address these challenges. They offer quicker and more accurate manipulation for cardiac and GI interventions, enhancing patient outcomes.
Minimally invasive surgery (MIS) has evolved as an effective method for cardiovascular diseases (CVDs) and gastrointestinal (GI) cancers. Recently, soft robotic catheters using soft materials have attracted considerable attention thanks to their ability to navigate through intricate anatomical structures and perform precisely controlled movements. However, current systems are powered by rigid pull-wire mechanism, showing substantial nonlinear hysteresis and high force loss. Furthermore, they require several actuators to manipulate the bending tip for working in the intricate anatomical corners of the internal organs. For thrombus removal, the approach of stent retrieval via a catheter has various drawbacks including difficult manipulation, insufficient retrieval force, and complexity. Herein, new soft robotic catheters are introduced to address these challenges. The new catheters can achieve bidirectional bending motion and spiral shapes using a single soft actuation source. They are equipped with a portable and ergonomic control interface. Mathematical models for the bending effector are developed and experimentally validated. The new soft robotic catheters potentially allow for quicker and more accurate manipulation to reach any target inside the cardiac and GI regions, enabling faster and more targeted ablation and thrombus removal therapy to enhance patient outcomes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available