4.5 Article

Particle Emission Characteristics of a Gas Turbine with a Double Annular Combustor

Journal

AEROSOL SCIENCE AND TECHNOLOGY
Volume 49, Issue 9, Pages 842-855

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1080/02786826.2015.1078452

Keywords

-

Funding

  1. European Aviation Safety Agency (EASA) [EASA.2010.FC.10, SC02]
  2. Federal Office of Civil Aviation, Switzerland (FOCA)
  3. EPSRC [EP/F034350/1] Funding Source: UKRI
  4. NERC [ncas10006] Funding Source: UKRI
  5. Engineering and Physical Sciences Research Council [EP/F034350/1] Funding Source: researchfish
  6. Natural Environment Research Council [ncas10006] Funding Source: researchfish

Ask authors/readers for more resources

The total climate, air quality, and health impact of aircraft black carbon (BC) emissions depend on quantity (mass and number concentration) as well as morphology (fractal dimension and surface area) of emitted BC aggregates. This study examines multiple BC emission metrics from a gas turbine with a double annular combustor, CFM56-5B4-2P. As a part of the SAMPLE III.2 campaign, concurrent measurements of particle mobility, particle mass, particle number concentration, and mass concentration, as well as collection of transmission electron microscopy (TEM) samples, allowed for characterization of the BC emissions. Mass-and number-based emission indices were strongly influenced by thrust setting during pilot combustion and ranged from <1 to 208 mg/kg-fuel and 3 x 10(12) to 3 x 10(16) particles/kg-fuel, respectively. Mobility measurements indicated that mean diameters ranged from 7 to 44 nm with a strong dependence on thrust during pilot-only combustion. Using aggregation and sintering theory with empirical effective density relationships, a power-law relationship between primary particle diameter and mobility diameter is presented. Mean primary particle diameter ranged from 6 to 19 nm; however, laser-induced incandescence (LII) and mass-mobility-calculated primary particle diameters demonstrated opposite trends with thrust setting. Similarly, mass-mobility-calculated aggregate mass specific surface area and LII-measured surface area were not in agreement, indicating both methods need further development and validation before use as quantitative indicators of primary particle diameter and mass-specific surface area.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available