4.7 Article

Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study

Journal

CLINICAL INFECTIOUS DISEASES
Volume 61, Issue 3, Pages 464-467

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/cid/civ263

Keywords

cryptococcal meningitis; cryptococcus; lateral flow assay; HIV; point-of-care systems

Funding

  1. National Institute of Allergy and Infectious Diseases [U01AI089244, R01NS086312, K24AI096925, T32AI055433, R25TW009345]
  2. FOGARTY INTERNATIONAL CENTER [R25TW009345] Funding Source: NIH RePORTER
  3. NATIONAL INSTITUTE OF ALLERGY AND INFECTIOUS DISEASES [T32AI055433, U01AI089244, K24AI096925] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE [R01NS086312] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Background. Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. Methods. From August 2013 to August 2014, CRAG LFA (IMMY, Norman, Oklahoma) tests were performed on fingerstick whole blood, plasma/serum, and CSF in 207 HIV-infected adults with suspected meningitis in Kampala, Uganda. Venous blood was also collected and centrifuged to obtain serum and/or plasma. CSF was tested after lumbar puncture. Results. Of 207 participants, 149 (72%) had fingerstick CRAG-positive results. There was 100% agreement between fingerstick whole blood and serum/plasma. Of the 149 fingerstick CRAG-positive participants, 138 (93%) had evidence of cryptococcal meningitis with a positive CSF CRAG. Eleven participants (5%) had isolated cryptococcal antigenemia with a negative CSF CRAG and culture, of whom 8 had CSF abnormalities (n = 3 lymphocytic pleocytosis, n = 5 elevated protein, n = 4 increased opening pressure). No persons with cryptococcal meningitis had negative fingersticks. Conclusions. The 100% agreement between whole blood, serum, and plasma CRAG LFA results demonstrates that fingerstick CRAG is a reliable bedside diagnostic test. Using point-of-care CRAG testing simplifies screening large numbers of patients and enables physicians to prioritize on whom to measure CSF opening pressure using manometers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available