4.7 Article

Inertial cavitation initiated by polytetrafluoroethylene nanoparticles under pulsed ultrasound stimulation

Journal

ULTRASONICS SONOCHEMISTRY
Volume 32, Issue -, Pages 1-7

Publisher

ELSEVIER
DOI: 10.1016/j.ultsonch.2016.02.009

Keywords

Inertial cavitation; PTFE nanoparticles; Interfacial nanobubbles; Passive cavitation detector; Free radical

Funding

  1. Ministry of Science and Technology, Taiwan [101-2221-E-007-035-MY3, 104-2221-E-007-076]
  2. National Tsing Hua University (Hsinchu, Taiwan) [105N522CE1]
  3. Chang Gung Memorial Hospital (Linkou, Taiwan) [CIRPD2E0051]

Ask authors/readers for more resources

Nanoscale gas bubbles residing on a macroscale hydrophobic surface have a surprising long lifetime (on the order of days) and can serve as cavitation nuclei for initiating inertial cavitation (IC). Whether interfacial nanobubbles (NBs) reside on the infinite surface of a hydrophobic nanoparticle (NP) and could serve as cavitation nuclei is unknown, but this would be very meaningful for the development of sonosensitive NPs. To address this problem, we investigated the IC activity of polytetrafluoroethylene (PTFE) NPs, which are regarded as benchmark superhydrophobic NPs due to their low surface energy caused by the presence of fluorocarbon. Both a passive cavitation detection system and terephthalic dosimetry was applied to quantify the intensity of IC. The IC intensities of the suspension with PTFE NPs were 10.30 and 48.41 times stronger than those of deionized water for peak negative pressures of 2 and 5 MPa, respectively. However, the IC activities were nearly completely inhibited when the suspension was degassed or ethanol was used to suspend PTFE NPs, and they were recovered when suspended in saturated water, which may indicates the presence of interfacial NBs on PTFE NPs surfaces. Importantly, these PTFE NPs could sustainably initiate IC for excitation by a sequence of at least 6000 pulses, whereas lipid microbubbles were completely depleted after the application of no more than 50 pulses under the same conditions. The terephthalic dosimetry has shown that much higher hydroxyl yields were achieved when PTFE NPs were present as cavitation nuclei when using ultrasound parameters that otherwise did not produce significant amounts of free radicals. These results show that superhydrophobic NPs may be an outstanding candidate for use in IC-related applications. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available