4.7 Article

Analysis and design recommendations for diagonally stiffened steel plate shear walls

Journal

THIN-WALLED STRUCTURES
Volume 103, Issue -, Pages 72-80

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2016.02.008

Keywords

Steel plate shear wall; Diagonal stiffener; Stiffness; Shear strength

Ask authors/readers for more resources

This paper presents a comparison of analytical and experimental results of an investigation on the diagonally stiffened steel plate shear walls (SPWs). Experimental studies were carried out on three 1/3-scaled, one story single bay shear walls. The first specimen was a control specimen which was unstiffened and the other two specimens were diagonally stiffened using different stiffener configurations. Finite-element models of full SPWs are developed using finite element model. The results are compared with experimental results to investigate the influence of stiffeners on the behavior of the specimens. Good agreement between analytical and experimental models is found in point of failure modes and specimens' behavior. Based on the theory of plates and shells and frame analysis an equation is proposed to calculate the strength of both stiffened and unstiffened SPWs which could predict the experimental results accurately. (C) 2016 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available