4.7 Article

Polypeptide with electroactive endgroups as sensing platform for the abused drug 'methamphetamine' by bioelectrochemical method

Journal

TALANTA
Volume 161, Issue -, Pages 789-796

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2016.09.042

Keywords

Polypeptide; Surface modification; Abused drug analysis; Methamphetamine; Immunosensor; Chromatography

Funding

  1. Industrial Thesis Support Program (SAN-TEZ) of Republic of Turkey
  2. Ministry of Science, Industry and Technology [0620.STZ.2014]
  3. Republic of Turkey, Ministry of Development [2016K121190]
  4. Ege University Research Fund through BAP project [16-FEN-004]
  5. Istanbul Technical University Research Fund
  6. TUBITAK

Ask authors/readers for more resources

Affinity-type sensors have emerged as outstanding platforms in the detection of diagnostic protein markers, nucleic acids and drugs. Thus, these novel platforms containing antibodies could be integrated into the monitoring systems for abused drugs. Herein, we established a novel detection platform for the analysis of a common illicit drug; methamphetamine (METH). Initially, a fluorescent-labeled polypeptide (EDOT-BTDA-Pala), derived from L-alanine N-carboxyanhydride (L-Ala-NCA) via ring-opening polymerization using 4,7-bis(2,3-dihydrothieno[3,4-b][1,4]dioxin-5-yl)benzo[c][1,2,5]thiadiazole-5,6-diamine (EDOT-NH2-BTDA) as initiator, was employed as a glassy carbon electrode (GCE) covering host, in order to immobilize the METH selective antibody. Prior to the examination of analytical features, GCE/EDOT-BTDA-Pala/Antibody surface was successfully characterized in the way of electrochemical (cyclic voltammetry and electrochemical impedance spectroscopy) and microscopic techniques (scanning electron microscopy and fluorescence microscopy). As for the analytical characterization, linearity and limit of detection (LOD) were found as 10-100 mu g/mL with an equation of y=0.0429x-0.2347, (R-2=0.996) and 13.07 mu g/mL, respectively. Moreover, sample application using artificial urine, saliva and serum samples spiked with METH (10, 25, 50 mu g/mL) were performed and LC-MS/MS system was used for further confirmation. The described platform can be adapted to monitor the other types of abused drugs by using suitably selected biorecognition elements.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available