4.7 Article

Imaging of local porosity/voids using a fully non-contact air-coupled transducer and laser Doppler vibrometer system

Journal

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/1475921716668843

Keywords

Non-contact inspection; air-coupled transducer; laser Doppler vibrometer; frequency-wavenumber filtering; porosity; voids; structural health monitoring; non-destructive evaluation

Funding

  1. Graduate Research Assistantship at National Institute of Aerospace through the Advanced Composites Project (ACP) at NASA Langley Research Center

Ask authors/readers for more resources

This study exploits the feasibility of imaging zones of local porosity/voids simulated by introducing microspheres during layup of a unidirectional carbon fiber-reinforced polymer composite panel. A fully non-contact hybrid system primarily composed of an air-coupled transducer and a laser Doppler vibrometer was used for imaging the local porosity/void zones from the guided wave response. To improve image resolution, several preprocessing techniques are performed. The wavefield reconstructed from the laser Doppler vibrometer measurements was first denoised using a one-dimensional wavelet transform in the time domain followed by a two-dimensional wavelet transform in the spatial domain. From the total wavefield, the much weaker backscattered waves were separated from the stronger incident wave by frequency-wavenumber domain filtering. In order to further enhance the signal-to-noise ratio and sharpen the image, the attenuation of incident wave propagation to the damage site was compensated through two proposed weight functions. Finally, a zero-lag cross-correlation was performed for imaging the zone where the compensated incident and backscattered waves were in phase. This improved imaging condition, the denoised weighted zero-lag cross-correlation, was proposed and tested for defect imaging in the composite panel with eight intentionally introduced zones of high porosity/voids of varying diameters (1.59-6.35mm) and depths (0.36-1.08mm). As expected, the sensitivity of the non-contact air-coupled transducer/laser Doppler vibrometer hybrid system was limited by the wavelength of the excitation signal. The system incorporated with the denoised weighted zero-lag cross-correlation imaging condition for guided wave interrogation gave similar image quality in comparison with that by the immersion C-scan.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available