4.6 Article

Blood Pressure and Adverse Events During Continuous Flow Left Ventricular Assist Device Support

Journal

CIRCULATION-HEART FAILURE
Volume 8, Issue 3, Pages 551-556

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCHEARTFAILURE.114.002000

Keywords

aortic valve insufficiency; blood pressure; cerebral hemorrhage; thrombosis

Ask authors/readers for more resources

Background Adverse events (AEs), such as intracranial hemorrhage, thromboembolic event, and progressive aortic insufficiency, create substantial morbidity and mortality during continuous flow left ventricular assist device support yet their relation to blood pressure control is underexplored. Methods and Results A multicenter retrospective review of patients supported for at least 30 days and 18 months by a continuous flow left ventricular assist device from June 2006 to December 2013 was conducted. All outpatient Doppler blood pressure (DOPBP) recordings were averaged up to the time of intracranial hemorrhage, thromboembolic event, or progressive aortic insufficiency. DOPBP was analyzed as a categorical variable grouped as high (>90 mm Hg; n=40), intermediate (80-90 mm Hg; n=52), and controlled (<80 mm Hg; n=31). Cumulative survival free from an AE was calculated using Kaplan-Meier curves and Cox hazard ratios were derived. Patients in the high DOPBP group had worse baseline renal function, lower angiotensin-converting enzyme inhibitor or angiotensin receptor blocker usage during continuous flow left ventricular assist device support, and a more prevalent history of hypertension. Twelve (30%) patients in the high DOPBP group had an AE, in comparison with 7 (13%) patients in the intermediate DOPBP group and only 1 (3%) in the controlled DOPBP group. The likelihood of an AE increased in patients with a high DOPBP (adjusted hazard ratios [95% confidence interval], 16.4 [1.8-147.3]; P=0.012 versus controlled and 2.6 [0.93-7.4]; P=0.068 versus intermediate). Overall, a similar association was noted for the risk of intracranial hemorrhage (P=0.015) and progressive aortic insufficiency (P=0.078) but not for thromboembolic event (P=0.638). Patients with an AE had a higher DOPBP (9010 mm Hg) in comparison with those without an AE (85 +/- 10 mm Hg; P=0.05). Conclusions In a population at risk, higher DOPBP during continuous flow left ventricular assist device support was significantly associated with a composite of AEs.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available