4.7 Article

Carbon fiber cloth-supported Au nanodendrites as a rugged surface-enhanced Raman scattering substrate and electrochemical sensing platform

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 225, Issue -, Pages 377-383

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2015.11.036

Keywords

Gold nanodendrite; Nanodendrite network porous structure; Carbon fiber cloth; Surface enhanced Raman scattering (SERS); Mercury detection

Funding

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT and Future Planning [2015R1A2A2A01006445]
  2. Viet Nam National Foundation for Science and Technology Development (NAFOSTED) [104.03-2011.42]
  3. National Research Foundation of Korea [2015R1A2A2A01006445] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

A carbon fiber cloth (CFC)-supported Au nanodendrite (CFC-AuND) prepared by simple electrodeposition of Au onto CFC has been demonstrated. The motivation of employing CFC was to fully incorporate its useful characteristics of flexibility, porosity, and conductivity in the development of substrates versatile for both surface-enhanced Raman scattering (SERS) and electrochemical measurements. To improve sample representation in SERS measurement, a wide area coverage (WAC) scheme able to cover an area of 28.3 mm(2) (illumination diameter: 6 mm) was used to compensate for the variation in Raman intensities of analytes adsorbed at different locations on the substrate. When a 1 nM 2-naphthalenethiol sample was measured using CFC-AuND, the corresponding Raman peaks were clearly observed and the substrate-to-substrate reproducibility of five separately prepared substrates was acceptable, with the relative standard deviation (RSD) of 8.5%. In addition, since the substrate was physically flexible, its SERS performance was not seriously degraded even after moderate bending. Next, the CFC-AuND substrate was used for the electrochemical detection of Hg(II) in aqueous samples by means of stripping voltammetry. The limit of detection (LOD) was 0.09 ppb and the substrate-to-substrate reproducibility was also superior, with RSDs below 3.6%. Overall, the results of the present work demonstrate the potential of CFC-AuND as a rugged, field-usable, cost-effective substrate for SERS and electrochemical measurements. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available