4.7 Article

An ultrasensitive fluorescence aptasensor for chloramphenicol based on FRET between quantum dots as donor and the magnetic SiO2@Au NPs probe as acceptor with exonuclease-assisted target recycling

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 222, Issue -, Pages 1066-1072

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2015.09.049

Keywords

Fluorescence aptasensor; Chloramphenicol; Exonuclease-assisted target recycling; FRET; SiO2@Au nanotracer

Funding

  1. National Natural Science Foundation of China [31070866]
  2. Natural Science Foundation of Zhejiang [LY13C200017, Y15B050008]
  3. Natural Science Foundation of Ningbo [2013A610241, 2013A610163, 2014A610184]
  4. Science and Technology Project of Zhejiang [2013C37033]
  5. State Administration of Grain [201313010]
  6. Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)
  7. K.C. Wong Magna Fund in Ningbo University

Ask authors/readers for more resources

In this work, a fluorescence aptasensor has been developed to detect trace chloramphenicol based on FRET and exonuclease-assisted target recycling. Firstly, the composite probe for CAP was prepared through the immunoreactions between the capture probe based on dsDNA antibody labeled on Fe3O4@Au nanoparticles and the nanotracer using double strand aptamer (aptamer hybrid with its complementary DNA) labeled on core-shell SiO2@Au. When the composite probe solution was mixed with CAP, the aptamer on the nanotracer preferentially bounded with CAP, and then released cDNA-SiO2@Au and CAP-Apt complex to the supernatant. This is because anti-DNA on capture probes can't recognize the ssDNA. The exonuclease I (Exo I) added into the supernatant can further digest the aptamer-CAP from the 3'-end of aptamer and release CAP again, which can further participate in new cycle to react with the probes. The supernatant containing numerous SiO2@Au could efficiently quench the fluorescence response of CdSe QDs by FRET. Experimental results showed the CAP detection owning a linearity range of 0.001-10 ng mL(-1) and detection of limit (LOD) of 0.0002 ng mL(-1). Besides, the results of our method for CAP detection in the fish samples agreed well with those from ELISA, verifying its accuracy and reliability. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available