4.6 Article

High Temperature Shear Horizontal Electromagnetic Acoustic Transducer for GuidedWave Inspection

Journal

SENSORS
Volume 16, Issue 4, Pages -

Publisher

MDPI
DOI: 10.3390/s16040582

Keywords

Electromagnetic Acoustic Transducers; EMAT; Guided Wave Testing; high temperature inspection

Funding

  1. European Commission [GA-SME-2013-1-605028]

Ask authors/readers for more resources

Guided Wave Testing (GWT) using novel Electromagnetic Acoustic Transducers (EMATs) is proposed for the inspection of large structures operating at high temperatures. To date, high temperature EMATs have been developed only for thickness measurements and they are not suitable for GWT. A pair of water-cooled EMATs capable of exciting and receiving Shear Horizontal (SH0) waves for GWT with optimal high temperature properties (up to 500 degrees C) has been developed. Thermal and Computational Fluid Dynamic (CFD) simulations of the EMAT design have been performed and experimentally validated. The optimal thermal EMAT design, material selection and operating conditions were calculated. The EMAT was successfully tested regarding its thermal and GWT performance from ambient temperature to 500 degrees C.