4.7 Article

Downscaling procedures reduce chemical use in androgen receptor reporter gene assay

Journal

SCIENCE OF THE TOTAL ENVIRONMENT
Volume 571, Issue -, Pages 826-833

Publisher

ELSEVIER
DOI: 10.1016/j.scitotenv.2016.07.059

Keywords

Downscaling; Miniaturization; Low-volume; Androgen receptor binders; Reporter gene bioassay; (Anti)androgens

Funding

  1. EU [290100]

Ask authors/readers for more resources

Bioactivity screening studies often face sample amount limitation with respect to the need for reliable, reproducible and quantitative results. Therefore approaches that minimize sample use are needed. Low-volume exposure and chemical dilution procedures were applied in an androgen receptor reporter gene human cell line assay to evaluate environmental contaminants and androgen receptor modulators, which were the agonist 5 alpha-dihydrotestosterone (DHT); and the antagonists flutamide, bisphenol A, 1-hydroxypyrene and triclosan. Cells were exposed in around 1/3 of the medium volume recommended by the protocol (70 mu L/well). Further, chemical losses during pipetting steps were minimized by applying a low-volume method for compound dilution in medium (250 mu L for triplicate wells) inside microvolume glass inserts. Simultaneously, compounds were evaluated following conventional procedures (200 mu L/well, dilution in 24-well plates) for comparison of results. Low volume exposure tests produced DHT EC50 (3.4-3.7 x 10(-10) M) and flutamide IC50 (2.2-3.3 x 10(-7) M) values very similar to those from regular assays (3.1-4.2 x 10(-10) and 2.1-33 x 10(-7) M respectively) and previous studies. Also, results were within assay acceptance criteria, supporting the relevance of the downscaling setup for agonistic and antagonistic tests. The low-volume exposure was also successful in determining IC50 values for 1-hydroxypyrene (2.1-2.8 x 10(-6) M), bisphenol A (2.6-33 x 10(-6) M), and triclosan (1.2-1.9 x 10(-6) M) in agreement with values obtained through high-volume exposure (2.3-2.8, 2.5-3.4 and 1.0-1.3 x 10(-6) M respectively). Finally, experiments following both low-volume dosing and exposure produced flutamide and triclosan IC50 values similar to those from regular tests. The low-volume experimental procedures provide a simple and effective solution for studies that need to minimize bioassay sample use while maintaining method reliability. The downscaling methods can be applied for the evaluation of samples, fractions or chemicals which require minimal losses during the steps of pipetting, transference to medium and exposure in bioassays. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available