4.6 Article

On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study

Journal

PLOS ONE
Volume 11, Issue 8, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0157655

Keywords

-

Funding

  1. EPSRC UK National Quantum Technology Hub for Sensors and Metrology [EP/M013294/1]
  2. Medical Research Council New Investigator Research Grant [MR/M006301/1]
  3. MRC
  4. EPSRC Partnership Grant [MR/K6010/86010/1]
  5. Engineering and Physical Sciences Research Council [EP/M013294/1, EP/E036473/1] Funding Source: researchfish
  6. Medical Research Council [MR/M006301/1, G0901321, MR/M009122/1] Funding Source: researchfish
  7. EPSRC [EP/E036473/1, EP/M013294/1] Funding Source: UKRI
  8. MRC [G0901321, MR/M006301/1, MR/M009122/1] Funding Source: UKRI

Ask authors/readers for more resources

Magnetoencephalography (MEG) is a sophisticated tool which yields rich information on the spatial, spectral and temporal signatures of human brain function. Despite unique potential, MEG is limited by a low signal-to-noise ratio (SNR) which is caused by both the inherently small magnetic fields generated by the brain, and the scalp-to-sensor distance. The latter is limited in current systems due to a requirement for pickup coils to be cryogenically cooled. Recent work suggests that optically-pumped magnetometers (OPMs) might be a viable alternative to superconducting detectors for MEG measurement. They have the advantage that sensors can be brought to within similar to 4 mm of the scalp, thus offering increased sensitivity. Here, using simulations, we quantify the advantages of hypothetical OPM systems in terms of sensitivity, reconstruction accuracy and spatial resolution. Our results show that a multichannel whole-head OPM system offers (on average) a fivefold improvement in sensitivity for an adult brain, as well as clear improvements in reconstruction accuracy and spatial resolution. However, we also show that such improvements depend critically on accurate forward models; indeed, the reconstruction accuracy of our simulated OPM system only outperformed that of a simulated superconducting system in cases where forward field error was less than 5%. Overall, our results imply that the realisation of a viable whole-head multi-channel OPM system could generate a step change in the utility of MEG as a means to assess brain electrophysiological activity in health and disease. However in practice, this will require both improved hardware and modelling algorithms.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available