4.6 Article

egs_brachy: a versatile and fast Monte Carlo code for brachytherapy

Journal

PHYSICS IN MEDICINE AND BIOLOGY
Volume 61, Issue 23, Pages 8214-8231

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0031-9155/61/23/8214

Keywords

brachytherapy; dosimetry; Monte Carlo; EGSnrc; egs_brachy; variance reduction techniques

Funding

  1. Natural Sciences and Engineering Research Council of Canada
  2. Canada Research Chairs program
  3. Ministry of Research and Innovation of Ontario

Ask authors/readers for more resources

egs_brachy is a versatile and fast Monte Carlo (MC) code for brachytherapy applications. It is based on the EGSnrc code system, enabling simulation of photons and electrons. Complex geometries are modelled using the EGSnrc C++ class library and egs_brachy includes a library of geometry models for many brachytherapy sources, in addition to eye plaques and applicators. Several simulation efficiency enhancing features are implemented in the code. egs_brachy is benchmarked by comparing TG-43 source parameters of three source models to previously published values. 3D dose distributions calculated with egs_brachy are also compared to ones obtained with the BrachyDose code. Well-defined simulations are used to characterize the effectiveness of many efficiency improving techniques, both as an indication of the usefulness of each technique and to find optimal strategies. Efficiencies and calculation times are characterized through single source simulations and simulations of idealized and typical treatments using various efficiency improving techniques. In general, egs_brachy shows agreement within uncertainties with previously published TG-43 source parameter values. 3D dose distributions from egs_brachy and BrachyDose agree at the sub-percent level. Efficiencies vary with radionuclide and source type, number of sources, phantom media, and voxel size. The combined effects of efficiency-improving techniques in egs_brachy lead to short calculation times: simulations approximating prostate and breast permanent implant (both with (2 mm)(3) voxels) and eye plaque (with (1 mm)(3) voxels) treatments take between 13 and 39s, on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core, to achieve 2% average statistical uncertainty on doses within the PTV. egs_brachy will be released as free and open source software to the research community.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available