4.2 Article

Electrode Location and Angular Insertion Depth Are Predictors of Audiologic Outcomes in Cochlear Implantation

Journal

OTOLOGY & NEUROTOLOGY
Volume 37, Issue 8, Pages 1016-1023

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MAO.0000000000001125

Keywords

Angular insertion depth; Cochlear implant; Electrode design; Electrode location; Scala tympani; Scalar translocation; Speech perception

Funding

  1. National Institute on Deafness and Other Communication Disorders [R01DC008408, R01DC014462, R01DC014037]
  2. National Center for Advancing Translational Sciences [UL1TR000445]

Ask authors/readers for more resources

Objectives: 1) Investigate the impact of electrode type and surgical approach on scalar electrode location; and 2) examine the relation between electrode location and postoperative audiologic performance. Setting: Tertiary academic hospital. Patients: Two hundred twenty post-lingually deafened adults undergoing cochlear implant (CI). Main Outcome Measures: Primary outcome measures of interest were scalar electrode location and postoperative audiologic performance. Results: In 68% of implants, electrodes were observed to be located solely in the scala tympani (ST). Multivariate analysis demonstrated perimodiolar (PM) and mid-scala (MS) electrodes were 22.4 (95% CI: 6.3-80.0, p<0.001) and 55.0 (95% CI: 9.7-312.8, p<0.001) times more likely to have at least one electrode in the scala vestibuli (SV) compared with lateral wall (LW) electrodes, respectively. Compared with cochleostomy (C), round window (RW) and extended round window (ERW) approaches demonstrated 70% reduction in SV insertion (RW: OR 0.28, 95% CI: 0.1-0.8, p = 0.01; ERW: OR 0.28, 95% CI: 0.1-0.7, p = 0.005). Examining postoperative audiometric performance, consonant-nucleus-consonant (CNC) score increased 0.6% with every 10 degrees increase in angular insertion depth beyond the group minimum of 208 degrees (coefficient 0.0006, 95% CI: 0.0001-0.001, p = 0.03). SV insertion was associated with a 12% decrease in CNC score (coefficient -0.12, 95% CI: -0.22 to -0.02, p = 0.02). CNC score decreased 0.3% for every 1 year increase in age (coefficient -0.003, 95% CI: -0.006 to -0.0006, p = 0.02). Conclusions: Electrode design and surgical approach were predictors of scalar electrode location. Specifically, LW electrodes showed higher rates of ST insertion compared with PM or MS. RW and ERW approaches showed higher rates of ST insertion when compared with C. In regards to performance, ST insertion, younger age, and greater angular insertion depth were predictors of improved CNC scores.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available